{"title":"Current Switch","description":"","products":[{"product_id":"furison-electric-fcs003","title":"Furison Electric FCS003, Self-Powered AC Current Switch, Dryer Switch, Input Rating 1.2 - 40A, Switch Rating 120Vac 2.5A","description":"\u003cp\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/KSL3V.pdf?v=1747208888\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSA1D03.pdf?v=1747373386\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSN1B05.pdf?v=1747373383\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSN1W05.pdf?v=1747373386\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSP1W03.pdf?v=1747373386\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSP1W05.pdf?v=1747373386\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSP1W10.pdf?v=1747373386\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/LVFSP1W15.pdf?v=1747373386\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Series_FCS003_AC_Current_Switch_Spec_Sheet.pdf?v=1783738836\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe series FCS003 current switch was designed for monitoring AC. By sensing AC, this device controls AC load on motor, relay, lighting, fan, and applicably monitored circuit, together with contactor. Input passing through current rang 1.2-- 40A, and maximum voltage load up to 120V\/2.5A. Delay module was Incorporated into the circuit for 5, 10, 15 minutes and zero time delays on action.\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eWith its high overload, accuracy, isolation, safety, low power consumption and strong interference resistance ability, this device has been already widely used in industrial automation. \u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"height: 352.688px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eStock Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003eFCS-003\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003ePower-supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003eNone, self-powered\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003eAmperage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e\u003cspan\u003e1.2 to 40A continuous\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003e\u003cspan\u003eConduct current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.5±0.2A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e(47×100×28.5)mm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003eSwitch state\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e\u003cspan\u003eNormal open\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003eOutput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e2.5A @ 120VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eAC load frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e10-200Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eHysteresis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e≤ 1% \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e10%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e100% \u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e≤ 1W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u0026lt;200ms \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003e\u003cspan\u003eLeakage current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e≤ 1mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eTemperature limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e32 to 122℉ (0 to 50℃ )\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"height: 19.5938px; width: 31.0469%;\"\u003e\u003cstrong\u003eHumidity limits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 19.5938px; width: 68.5921%;\"\u003e\u003cstrong\u003e10 to 95% RH (none-condensing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\n\u003cstrong\u003eUL 94V-0 flammability rated ABS, insulation \u003c\/strong\u003e\u003cstrong\u003eclass 600 V\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 31.0469%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.5921%; height: 19.5938px;\"\u003e\u003cstrong\u003e200% (\u0026lt; 200% of the rated cross-core current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Furison Electric","offers":[{"title":"1.2-40A","offer_id":53459067011366,"sku":"FCS003","price":34.88,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/FCS003.jpg?v=1783740010"}],"url":"https:\/\/auroraindustry.com\/collections\/current-switch.oembed","provider":"AuroraIndustry.com","version":"1.0","type":"link"}