{"title":"Medium Voltage Fuses","description":"","products":[{"product_id":"littelfuse-702r1c8-25","title":"Littelfuse R-Rated 70A Medium Voltage Fuse, Current-Limiting, 2R Size, Single Barrel, Cartridge Style, 8250Vac, 702R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 70A","offer_id":47299448340774,"sku":"702R1C8.25","price":1270.35,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_78811440-9756-4798-9e5f-59d8f4a955e9.jpg?v=1701741900"},{"product_id":"littelfuse-1003r1c8-25","title":"Littelfuse R-Rated 100A Medium Voltage Fuse, Current-Limiting, 3R Size, Single Barrel, Cartridge Style, 8250Vac, 1003R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 100A","offer_id":47299591471398,"sku":"1003R1C8.25","price":1258.14,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_8e55b211-c178-4c24-a807-000b3c3fca38.jpg?v=1701744234"},{"product_id":"littelfuse-1304r1c8-25","title":"Littelfuse R-Rated 130A Medium Voltage Fuse, Current-Limiting, 4R Size, Single Barrel, Cartridge Style, 8250Vac, 1304R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 130A","offer_id":47299607953702,"sku":"1304R1C8.25","price":1258.14,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_1ee4867c-2593-4bc3-a36b-8f21be8813e2.jpg?v=1701744491"},{"product_id":"littelfuse-1505r1c8-25","title":"Littelfuse R-Rated 150A Medium Voltage Fuse, Current-Limiting, 5R Size, Single Barrel, Cartridge Style, 8250Vac, 1505R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 150A","offer_id":47299623125286,"sku":"1505R1C8.25","price":1789.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_965e8a31-7849-4b86-845f-16e50e730c36.jpg?v=1701744740"},{"product_id":"littelfuse-1706r1c8-25","title":"Littelfuse R-Rated 170A Medium Voltage Fuse, Current-Limiting, 6R Size, Single Barrel, Cartridge Style, 8250Vac, 1706R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 170A","offer_id":47299690791206,"sku":"1706R1C8.25","price":2293.51,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_11062563-ca0d-4f0f-9484-48590c069951.jpg?v=1701745391"},{"product_id":"littelfuse-2009r1c8-25","title":"Littelfuse R-Rated 200A Medium Voltage Fuse, Current-Limiting, 9R Size, Single Barrel, Cartridge Style, 8250Vac, 2009R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 200A","offer_id":47299701932326,"sku":"2009R1C8.25","price":2315.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_a03bbe80-c294-4f18-96f1-2425db56b5af.jpg?v=1701745558"},{"product_id":"littelfuse-23012r1c8-25","title":"Littelfuse R-Rated 230A Medium Voltage Fuse, Current-Limiting, 12R Size, Single Barrel, Cartridge Style, 8250Vac, 23012R1C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 230A","offer_id":47299709337894,"sku":"23012R1C8.25","price":2315.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_79ddc7e2-eac1-4ad6-a005-07356b2cdc93.jpg?v=1701745712"},{"product_id":"littelfuse-39018r2c8-25","title":"Littelfuse R-Rated 390A Medium Voltage Fuse, Current-Limiting, 18R Size, Double Barrels, Cartridge Style, 8250Vac, 39018R2C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 390A","offer_id":47299717955878,"sku":"39018R2C8.25","price":3953.49,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_941c3002-9919-4e4b-a72d-fa3373a86232.jpg?v=1701745843"},{"product_id":"littelfuse-45024r2c8-25","title":"Littelfuse R-Rated 450A Medium Voltage Fuse, Current-Limiting, 24R Size, Double Barrels, Cartridge Style, 8250Vac, 45024R2C8.25","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"8250VAC \/ 450A","offer_id":47299732341030,"sku":"45024R2C8.25","price":3953.49,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_11af70c4-27b8-46ca-a0dd-111771834da8.jpg?v=1701746212"},{"product_id":"littelfuse-702r1c2-75","title":"Littelfuse R-Rated 70A Medium Voltage Fuse, Current-Limiting, 2R Size, Single Barrel, Cartridge Style, 2750Vac, 702R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 70A","offer_id":47299746201894,"sku":"702R1C2.75","price":1151.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_83621c05-488c-4f10-81a0-228f9a4db1a0.jpg?v=1701746495"},{"product_id":"littelfuse-1003r1c2-75","title":"Littelfuse R-Rated 100A Medium Voltage Fuse, Current-Limiting, 3R Size, Single Barrel, Cartridge Style, 2750Vac, 1003R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 100A","offer_id":47299768811814,"sku":"1003R1C2.75","price":1140.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_7af73ff9-729f-447b-aa36-3bcf2eaafb6b.jpg?v=1701746944"},{"product_id":"littelfuse-1304r1c2-75","title":"Littelfuse R-Rated 130A Medium Voltage Fuse, Current-Limiting, 4R Size, Single Barrel, Cartridge Style, 2750Vac, 1304R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 130A","offer_id":47299775136038,"sku":"1304R1C2.75","price":1140.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_4ac196f2-4ade-4264-afa2-db1a53efdc0d.jpg?v=1701747088"},{"product_id":"littelfuse-1505r1c2-75","title":"Littelfuse R-Rated 150A Medium Voltage Fuse, Current-Limiting, 5R Size, Single Barrel, Cartridge Style, 2750Vac, 1505R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 150A","offer_id":47299789226278,"sku":"1505R1C2.75","price":1412.97,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_5ed98e48-3efe-44da-9e5e-66bf118bba9f.jpg?v=1701747302"},{"product_id":"littelfuse-1706r1c2-75","title":"Littelfuse R-Rated 170A Medium Voltage Fuse, Current-Limiting, 6R Size, Single Barrel, Cartridge Style, 2750Vac, 1706R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 170A","offer_id":47299795288358,"sku":"1706R1C2.75","price":1923.85,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_e3c673cc-8745-48eb-8654-ddba14d62497.jpg?v=1701747446"},{"product_id":"littelfuse-2009r1c2-75","title":"Littelfuse R-Rated 200A Medium Voltage Fuse, Current-Limiting, 9R Size, Single Barrel, Cartridge Style, 2750Vac, 2009R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 200A","offer_id":47299799515430,"sku":"2009R1C2.75","price":1942.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_73d8464c-2b71-4e48-820d-e1d13d29d118.jpg?v=1701747585"},{"product_id":"littelfuse-23012r1c2-75","title":"Littelfuse R-Rated 230A Medium Voltage Fuse, Current-Limiting, 12R Size, Single Barrel, Cartridge Style, 2750Vac, 23012R1C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 230A","offer_id":47299803611430,"sku":"23012R1C2.75","price":1942.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_103e4c8e-0a0b-471f-a76b-b6c972de453e.jpg?v=1701747722"},{"product_id":"littelfuse-39018r2c2-75","title":"Littelfuse R-Rated 390A Medium Voltage Fuse, Current-Limiting, 18R Size, Double Barrels, Cartridge Style, 2750Vac, 39018R2C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 390A","offer_id":47299808985382,"sku":"39018R2C2.75","price":3138.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_c06fb4c5-31b7-4299-a487-ff7fd53125ab.jpg?v=1701747883"},{"product_id":"littelfuse-45024r2c2-75","title":"Littelfuse R-Rated 450A Medium Voltage Fuse, Current-Limiting, 24R Size, Double Barrels, Cartridge Style, 2750Vac, 45024R2C2.75","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"2750VAC \/ 450A","offer_id":47299836903718,"sku":"45024R2C2.75","price":3138.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_f2936dea-d32b-4cb5-852d-14a944200512.jpg?v=1701748044"},{"product_id":"littelfuse-702r1c5-5","title":"Littelfuse R-Rated 70A Medium Voltage Fuse, Current-Limiting, 2R Size, Single Barrel, Cartridge Style, 5500Vac, 702R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 70A","offer_id":47299841851686,"sku":"702R1C5.5","price":1234.76,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_a148c656-d48e-491e-baae-396c5ff9fc36.jpg?v=1701748181"},{"product_id":"littelfuse-1003r1c5-5","title":"Littelfuse R-Rated 100A Medium Voltage Fuse, Current-Limiting, 3R Size, Single Barrel, Cartridge Style, 5500Vac, 1003R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 100A","offer_id":47299860988198,"sku":"1003R1C5.5","price":1222.88,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_f9e42dd9-4484-494d-b5da-662eb008b27e.jpg?v=1701748720"},{"product_id":"littelfuse-1304r1c5-5","title":"Littelfuse R-Rated 130A Medium Voltage Fuse, Current-Limiting, 4R Size, Single Barrel, Cartridge Style, 5500Vac, 1304R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 130A","offer_id":47300077420838,"sku":"1304R1C5.5","price":1222.88,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_4561a641-2825-4e87-bd9b-57ffed62c050.jpg?v=1701753389"},{"product_id":"littelfuse-1505r1c5-5","title":"Littelfuse R-Rated 150A Medium Voltage Fuse, Current-Limiting, 5R Size, Single Barrel, Cartridge Style, 5500Vac, 1505R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 150A","offer_id":47300089184550,"sku":"1505R1C5.5","price":1610.15,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_f3987c4c-3ae3-4d72-87ff-fc49a5f77224.jpg?v=1701753575"},{"product_id":"littelfuse-1706r1c5-5","title":"Littelfuse R-Rated 170A Medium Voltage Fuse, Current-Limiting, 6R Size, Single Barrel, Cartridge Style, 5500Vac, 1706R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 170A","offer_id":47300096229670,"sku":"1706R1C5.5","price":2098.29,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_e3433180-22fe-42c5-9654-47f454cd78da.jpg?v=1701753716"},{"product_id":"littelfuse-2009r1c5-5","title":"Littelfuse R-Rated 200A Medium Voltage Fuse, Current-Limiting, 9R Size, Single Barrel, Cartridge Style, 5500Vac, 2009R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 200A","offer_id":47300103307558,"sku":"2009R1C5.5","price":2118.67,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_1420313e-0fde-43ff-9efd-db066d819b42.jpg?v=1701753845"},{"product_id":"littelfuse-23012r1c5-5","title":"Littelfuse R-Rated 230A Medium Voltage Fuse, Current-Limiting, 12R Size, Single Barrel, Cartridge Style, 5500Vac, 23012R1C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 230A","offer_id":47300114219302,"sku":"23012R1C5.5","price":2118.67,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_4a416de8-276b-499e-b42d-e7e76ffda56f.jpg?v=1701754007"},{"product_id":"littelfuse-39018r2c5-5","title":"Littelfuse R-Rated 390A Medium Voltage Fuse, Current-Limiting, 18R Size, Double Barrels, Cartridge Style, 5500Vac, 39018R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 390A","offer_id":47300120314150,"sku":"39018R2C5.5","price":3523.93,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_59f95659-853c-4d34-8beb-42b60fb81a72.jpg?v=1701754158"},{"product_id":"littelfuse-45024r2c5-5","title":"Littelfuse R-Rated 450A Medium Voltage Fuse, Current-Limiting, 24R Size, Double Barrels, Cartridge Style, 5500Vac, 45024R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 450A","offer_id":47300134011174,"sku":"45024R2C5.5","price":3203.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_740ca03f-7f39-4753-8968-63910c41223b.jpg?v=1701754317"},{"product_id":"littelfuse-48026r2c5-5","title":"Littelfuse R-Rated 480A Medium Voltage Fuse, Current-Limiting, 26R Size, Double Barrels, Cartridge Style, 5500Vac, 48026R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 480A","offer_id":47300148724006,"sku":"48026R2C5.5","price":3869.51,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_f0b5176d-6147-464d-ac46-74cb7846c5f5.jpg?v=1701754484"},{"product_id":"littelfuse-55030r2c5-5","title":"Littelfuse R-Rated 550A Medium Voltage Fuse, Current-Limiting, 30R Size, Double Barrels, Cartridge Style,  5500Vac, 55030R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 550A","offer_id":47300161536294,"sku":"55030R2C5.5","price":3869.51,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_9b1784ac-f737-4fd8-bb62-b0d89453e24f.jpg?v=1701754644"},{"product_id":"littelfuse-55030r3c5-5","title":"Littelfuse R-Rated 550A Medium Voltage Fuse, Current-Limiting, 30R Size, Triple Barrels, Cartridge Style, 5500Vac, 55030R3C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 550A","offer_id":47300175790374,"sku":"55030R3C5.5","price":4399.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_873c6d9d-a6ae-4bf4-a561-fef1954ebff7.jpg?v=1701754832"},{"product_id":"littelfuse-60032r2c5-5","title":"Littelfuse R-Rated 600A Medium Voltage Fuse, Current-Limiting, 32R Size, Double Barrels, Cartridge Style, 5500Vac, 60032R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 600A","offer_id":47300190961958,"sku":"60032R2C5.5","price":4062.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_76805752-1d4e-4f77-aadc-af2a5c6c755b.jpg?v=1701755081"},{"product_id":"littelfuse-60032r3c5-5","title":"Littelfuse R-Rated 600A Medium Voltage Fuse, Current-Limiting, 32R Size, Triple Barrels, Cartridge Style, 5500Vac, 60032R3C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 600A","offer_id":47300202103078,"sku":"60032R3C5.5","price":4755.56,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_3d66b637-04e7-4d7b-8374-e6d8739235c5.jpg?v=1701755261"},{"product_id":"littelfuse-65036r2c5-5","title":"Littelfuse R-Rated 650A Medium Voltage Fuse, Current-Limiting, 36R Size, Double Barrels, Cartridge Style, 5500Vac, 65036R2C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 650A","offer_id":47300210688294,"sku":"65036R2C5.5","price":4240.46,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_6de57c13-441e-4849-b425-4a67dd9aa1dd.jpg?v=1701755385"},{"product_id":"littelfuse-65036r3c5-5","title":"Littelfuse R-Rated 650A Medium Voltage Fuse, Current-Limiting, 36R Size, Triple Barrels, Cartridge Style, 5500Vac, 65036R3C5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 650A","offer_id":47300220289318,"sku":"65036R3C5.5","price":4700.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_6ab24944-9d3d-48b5-bd1e-d0337e5c8a2f.jpg?v=1701755520"},{"product_id":"littelfuse-702r1c5-5x","title":"Littelfuse R-Rated 70A Medium Voltage Fuse, Current-Limiting, 2R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 702R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 70A","offer_id":47300238016806,"sku":"702R1C5.5X","price":1299.49,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_bc7e1304-7e4e-4aaa-bee7-7965f60740bf.jpg?v=1701755748"},{"product_id":"littelfuse-1003r1c5-5x","title":"Littelfuse R-Rated 100A Medium Voltage Fuse, Current-Limiting, 5500Vac, 3R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 1003R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 100A","offer_id":47300288184614,"sku":"1003R1C5.5X","price":1286.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_750dece7-791c-4aaa-a4a4-4be0f62e30f1.jpg?v=1701756533"},{"product_id":"littelfuse-1304r1c5-5x","title":"Littelfuse R-Rated 130A Medium Voltage Fuse, Current-Limiting, 4R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 1304R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 130A","offer_id":47300310597926,"sku":"1304R1C5.5X","price":1286.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_31b60ad0-c3bf-4a52-9053-ec430b9b33ac.jpg?v=1701756919"},{"product_id":"littelfuse-1505r1c5-5x","title":"Littelfuse R-Rated 150A Medium Voltage Fuse, Current-Limiting, 5R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 1505R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 150A","offer_id":47300323115302,"sku":"1505R1C5.5X","price":1677.27,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_924dd739-5612-4652-924d-cdf79cdda901.jpg?v=1701757129"},{"product_id":"littelfuse-1706r1c5-5x","title":"Littelfuse R-Rated 170A Medium Voltage Fuse, Current-Limiting, 6R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 1706R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 170A","offer_id":47300344545574,"sku":"1706R1C5.5X","price":2034.04,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_d7510a3a-70a6-4db6-9371-8f624e9b789d.jpg?v=1701757394"},{"product_id":"littelfuse-2009r1c5-5x","title":"Littelfuse R-Rated 200A Medium Voltage Fuse, Current-Limiting, 9R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 2009R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 200A","offer_id":47300367352102,"sku":"2009R1C5.5X","price":2053.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_45028977-9820-4ff5-9236-ab2fc21a743a.jpg?v=1701757572"},{"product_id":"littelfuse-23012r1c5-5x","title":"Littelfuse R-Rated 230A Medium Voltage Fuse, Current-Limiting, 12R Size, Single Barrel, Cartridge Style, 14\" Clip Centers, 5500Vac, 23012R1C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 230A","offer_id":47300383965478,"sku":"23012R1C5.5X","price":2053.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_4b7f257f-322b-4eb5-af08-3e2ab018546d.jpg?v=1701757713"},{"product_id":"littelfuse-39018r2c5-5x","title":"Littelfuse R-Rated 390A Medium Voltage Fuse, Current-Limiting, 18R Size, Double Barrels, Cartridge Style, 14\" Clip Centers, 5500Vac, 39018R2C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 390A","offer_id":47300409065766,"sku":"39018R2C5.5X","price":3595.87,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_6a78f054-f6ed-4c65-9a6f-72c10409daea.jpg?v=1701757920"},{"product_id":"littelfuse-45024r2c5-5x","title":"Littelfuse R-Rated 450A Medium Voltage Fuse, Current-Limiting, 24R Size, Double Barrels, Cartridge Style, 14\" Clip Centers, 5500Vac, 45024R2C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 450A","offer_id":47300422762790,"sku":"45024R2C5.5X","price":3595.87,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_ac619755-6db9-49ec-94d4-05cc8ad86fc6.jpg?v=1701758036"},{"product_id":"littelfuse-55030r2c5-5x","title":"Littelfuse R-Rated 550A Medium Voltage Fuse, Current-Limiting, 30R Size, Double Barrels, Cartridge Style, 14\" Clip Centers, 5500Vac, 55030R2C5.5X","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/R-RATED.pdf?v=1701758825\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large short-circuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for R-rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the R rating. For example, a fuse with a 2R rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 550A","offer_id":47300439146790,"sku":"55030R2C5.5X","price":3948.46,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_85726049-bc9a-4393-9a62-118cb7135c89.jpg?v=1701758167"},{"product_id":"littelfuse-10e1cl5-5","title":"Littelfuse E-Rated 10A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 10E Size, 5500Vac, 10E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 10A","offer_id":47300636311846,"sku":"10E1CL5.5","price":1724.23,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_e8e110d9-f27a-4c2f-98b5-e9a0c6ba9a34.jpg?v=1701760696"},{"product_id":"littelfuse-15e1cl5-5","title":"Littelfuse E-Rated 15A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 15E Size, 5500Vac, 15E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 15A","offer_id":47300696539430,"sku":"15E1CL5.5","price":1724.23,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_56c99a79-5a7e-4751-9a57-6ef83915266f.jpg?v=1701761493"},{"product_id":"littelfuse-20e1cl5-5","title":"Littelfuse E-Rated 20A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 20E Size, 5500Vac, 20E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 20A","offer_id":47300711743782,"sku":"20E1CL5.5","price":1740.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_9641368f-ba16-47d4-ad91-655bd5913535.jpg?v=1701761647"},{"product_id":"littelfuse-25e1cl5-5","title":"Littelfuse E-Rated 25A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 25E Size, 5500Vac, 25E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 25A","offer_id":47300719313190,"sku":"25E1CL5.5","price":1740.98,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_109d194a-8dab-4f63-89bd-392c2a65a8e8.jpg?v=1701761773"},{"product_id":"littelfuse-30e1cl5-5","title":"Littelfuse E-Rated 30A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 30E Size, 5500Vac, 30E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 30A","offer_id":47300732354854,"sku":"30E1CL5.5","price":1963.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_cd574fef-99d1-446c-809d-7af211e0ef9e.jpg?v=1701762012"},{"product_id":"littelfuse-40e1cl5-5","title":"Littelfuse E-Rated 40A Medium Voltage Fuse, Current-Limiting, Clip Lock Design, 40E Size, 5500Vac, 40E1CL5.5","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/11.pdf_1.pdf?v=1701850248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eE-rated fuses have time current characteristics designed to provide current-limiting protection for power transformers, potential transformers, power centers, feeder centers, and unit sub stations. When properly applied, they can protect against high and low fault currents. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNEMA Standards for E-rated medium voltage fuses require that fuses rated 100E or less open within 300 seconds (5 minutes) when subjected to an RMS value of 200-240% of the fuse continuous current rating; and fuses with an E rating larger than 100E must open within 600 seconds (10 minutes) when subjected to an RMS current of 220- 240% of the fuse’s continuous current rating. These values establish one point on the time-current curve.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Littelfuse","offers":[{"title":"5500VAC \/ 40A","offer_id":47300740776230,"sku":"40E1CL5.5","price":1963.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/89_fc15c8cd-ddfa-4cac-a938-b19c90fd14f0.jpg?v=1701762133"}],"url":"https:\/\/auroraindustry.com\/collections\/medium-voltage-fuses.oembed?page=30","provider":"AuroraIndustry.com","version":"1.0","type":"link"}