{"title":"Motor and Pump Protection Relays","description":"","products":[{"product_id":"littelfuse-pgr-6101-120","title":"Littelfuse PGR-6101-120, PGR-6101 Series, Ground-Fault \u0026 Insulation Monitor, 120VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T112229.973.pdf?v=1697512962\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe PGR-6101 combines the features of a ground-fault protection relay and insulation monitor into one unit. It protects against ground faults by monitoring insulation resistance when the motor is de-energized and by monitoring ground-fault current when the motor is energized. The PGR-6101 features two separate analog outputs for optional current and ohm meters, and two separate alarm relays. It operates on one- or three-phase solidly grounded, resistance grounded and ungrounded systems up to 6 kV.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eIEEE Device Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eGround Fault (50G\/N, 51G\/N),\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGround detector (64), Alarm Relay (74)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSee ordering information\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eH 75 mm (3”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 100 mm (3.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 115 mm (4.5”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eResponse delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e\u0026lt; 50 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eContact Operating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSelectable fail-safe or non-fail-safe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eHarmonic Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eTest Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eReset Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCT-Loop Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTwo Form C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e0-1 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eApplicable Standards \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Listed (E183688) (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"120VAC","offer_id":47402954719526,"sku":"PGR-6101-120","price":3676.81,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/25_ab90f893-6e99-4fdb-ab9b-9a23e73ccf7e.jpg?v=1703813277"},{"product_id":"littelfuse-pgr-6100-120","title":"Littelfuse PGR-6100-120, PGR-6100 Series, Ground-Fault \u0026 Insulation Monitor, 120VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0726\/4088\/9126\/files\/media_3bb2f729-28cc-49bc-9548-47e4c486a084.pdf?v=1703813604\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe PGR-6100 monitor combines the features of a ground-fault protection relay and insulation monitor into one unit. The monitor can detect a motor ground fault whether the motor is running (online mode) or stopped (offline mode). It protects against ground faults by monitoring insulation resistance when the motor is de-energized and by monitoring ground-fault current when the motor is energized. The PGR-6100 features two separate analog outputs for optional current and ohm meters and two separate alarm relays. The unit operates on one- or three-phase solidly grounded, resistance grounded, and ungrounded systems up to 6 kV. Selectable fail-safe or non-fail safe operating modes allow connections to shunt or undervoltage breaker coils. The PGR-6100 is unique in that it has predictive as well as protective capabilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eIEEE Device Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eGround Fault (50G\/N, 51G\/N), \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGround detector (64), Alarm Relay (74)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSee ordering information\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eH 75 mm (3”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 100 mm (3.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 115 mm (4.5”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eResponse delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e\u0026lt; 250 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eContact Operating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSelectable fail-safe or non-fail-safe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eHarmonic Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eTest Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eReset Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCT-Loop Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTwo Form C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e0-1 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eApplicable Standards \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Listed (E183688) (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL         UL Listed (E183688) (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"120VAC","offer_id":47402974544166,"sku":"PGR-6100-120","price":3344.71,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/24_2ec18b67-c650-4328-b18b-65b97ac67cee.jpg?v=1703813695"},{"product_id":"littelfuse-pgr-6100-240","title":"Littelfuse PGR-6100-240, PGR-6100 Series, Ground-Fault \u0026 Insulation Monitor, 240VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0726\/4088\/9126\/files\/media_3bb2f729-28cc-49bc-9548-47e4c486a084.pdf?v=1703813604\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe PGR-6100 monitor combines the features of a ground-fault protection relay and insulation monitor into one unit. The monitor can detect a motor ground fault whether the motor is running (online mode) or stopped (offline mode). It protects against ground faults by monitoring insulation resistance when the motor is de-energized and by monitoring ground-fault current when the motor is energized. The PGR-6100 features two separate analog outputs for optional current and ohm meters and two separate alarm relays. The unit operates on one- or three-phase solidly grounded, resistance grounded, and ungrounded systems up to 6 kV. Selectable fail-safe or non-fail safe operating modes allow connections to shunt or undervoltage breaker coils. The PGR-6100 is unique in that it has predictive as well as protective capabilities.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eIEEE Device Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eGround Fault (50G\/N, 51G\/N), \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGround detector (64), Alarm Relay (74)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSee ordering information\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eH 75 mm (3”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 100 mm (3.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 115 mm (4.5”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eResponse delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e\u0026lt; 250 ms\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eContact Operating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSelectable fail-safe or non-fail-safe\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eHarmonic Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eTest Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eReset Button\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCT-Loop Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTwo Form C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e0-1 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eApplicable Standards \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Listed (E183688) (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL         UL Listed (E183688) (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"240VAC","offer_id":47402976575782,"sku":"PGR-6100-240","price":3344.71,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/24_90e61e6f-dcb6-4e75-9151-d3559b71dede.jpg?v=1703813811"},{"product_id":"littelfuse-mpu-32-00-01","title":"Littelfuse MPU-32-00-01, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232, Onboard inputs for 1-A phase CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47402992304422,"sku":"MPU-32-00-01","price":5530.45,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_d4d32723-4e2f-4283-a4d4-792f8d30a932.jpg?v=1703814104"},{"product_id":"littelfuse-mpu-32-00-00","title":"Littelfuse MPU-32-00-00, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232, Using MPU-CIM-00-00, purchased separately","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403006918950,"sku":"MPU-32-00-00","price":5530.45,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_a60c9618-3aee-435d-bd30-03d64b9f9cf4.jpg?v=1703814437"},{"product_id":"littelfuse-mpu-32-01-01","title":"Littelfuse MPU-32-01-01, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 TIA-485, Onboard inputs for 1-A phase CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403021893926,"sku":"MPU-32-01-01","price":6497.77,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_bf3a4977-2612-47b0-998d-a7683d9cac71.jpg?v=1703814847"},{"product_id":"littelfuse-mpu-32-01-00","title":"Littelfuse  MPU-32-01-00, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 TIA-485, Using MPU-CIM-00-00, purchased separately","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403026415910,"sku":"MPU-32-01-00","price":6497.77,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_5c3c8f17-f265-4e36-8984-dcdedb029220.jpg?v=1703814975"},{"product_id":"littelfuse-mpu-32-02-01","title":"Littelfuse MPU-32-02-01, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 DeviceNet, Onboard inputs for 1-A phase CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403031691558,"sku":"MPU-32-02-01","price":6559.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_07bba3eb-b23a-4d53-aa98-b172a5c845c8.jpg?v=1703815180"},{"product_id":"littelfuse-mpu-32-02-00","title":"Littelfuse MPU-32-02-00, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 DeviceNet, Using MPU-CIM-00-00, purchased separately","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403039555878,"sku":"MPU-32-02-00","price":6559.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_293a6fa9-c101-4722-aad8-90b18c4a032b.jpg?v=1703815297"},{"product_id":"littelfuse-mpu-32-04-01","title":"Littelfuse MPU-32-04-01, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 EtherNet\/IP \u0026 Modbus TCP, Onboard inputs for 1-A phase CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403088118054,"sku":"MPU-32-04-01","price":6620.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_cdebeed4-c966-463e-9dd4-ba3536a37107.jpg?v=1703816729"},{"product_id":"littelfuse-mpu-32-04-00","title":"Littelfuse MPU-32-04-00, MPU-32 Series, Motor Protection Unit, 65-265VAC\/80-275DC, TIA-232 \u0026 EtherNet\/IP \u0026 Modbus TCP, Using MPU-CIM-00-00, purchased separately","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140307.617.pdf?v=1697522600\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPU-32 series Motor Protection Unit is used to provide current and temperature-based protection, metering, and datalogging for three-phase, low-voltage, medium-horsepower induction motors. This relay is ideal for retrofitting and upgrading obsolete or aging motor protection using existing CTs. The MPU-32 can be programmed using the front-panel operator interface, the TIA-232 port, or an optional communications network. See the PMA Family of Panel Mount Adapter Kits to replace common obsolete relays.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e Motor Protection Unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Three ac-current inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage-CT input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24 V dc source for digital input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Programmable 4–20-mA analog output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Onboard temperature-sensor input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 100-Ω-Platinum RTD or PTC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Three programmable output relays\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Local RS-232 communications, optional network communications\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• PC-interface software (SE-Comm-RIS)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 line x 20 character backlit LCD display\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Keypad for programming and display selection\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 4 LEDs; 1 user programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overcurrent (50, 51), Jam, Ground fault (50G\/N, 51G\/N), PTC overtemperature (49), RTD temperature (38, 49), Unbalance (current) (46), Starts per hour (66), Differential (87), Phase loss (current) (46), Undercurrent (37)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 V ac, 25 VA; 80-275 V dc, 25 W \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eThree Form C programmables\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTIA-232 (standard); TIA-485, DeviceNet™, Ethernet (optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e4-20 mA, programmable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel (standard), Surface (with MPU-32-SMK converter kit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCurrent Input Module Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eDIN, Surface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA, Canada and USA\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14, CSA C22.2 No. 213-M1987 (RTD module only), CSA E60079-15:02 (RTD module only))\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eEN 60255-26, IEC 61010-1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eUL Recognized (UL 508, UL 1053, UL 60079-15 (RTD module only))\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403663753510,"sku":"MPU-32-04-00","price":6620.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/143_523a2e61-f865-439c-86c5-eb4583358fae.jpg?v=1703828920"},{"product_id":"littelfuse-mps-ctu-01-00","title":"Littelfuse MPS-CTU-01-00, MPS Series, Motor Protection System, 65-265VAC\/80-275DC, RS-485","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140418.171.pdf?v=1697522677\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPS Motor Protection System monitors voltage, current, and temperature to provide a comprehensive package of 22 protective functions. The MPS is a modular system with integrated protection, motor control, metering, and data-logging functions. This system is typically used to provide protection for three-phase low- and medium-voltage, medium- to highhorsepower induction motors.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eControl Unit (MPS-CTU)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Current inputs—5-A or 1-A secondary phase current transformers\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Voltage inputs—up to 600 V without PTs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage input—5-A or 1-A secondary or sensitive transformer\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Tachometer (high-speed pulse) input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 8 digital inputs, 5 relay outputs, 1 analog input and output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24-Vdc supply for OPI and RTD modules, and for digital inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• IRIG-B time-code input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/2 DIN size, surface mount\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• RS-485 network communications (Standard)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• DeviceNet™, Profibus®, or Ethernet communications available\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overfrequency (81), Overcurrent (50, 51), Jam, Underfrequency (81), Ground fault (50G\/N, 51G\/N), Undercurrent (37), Unbalance (voltage) (47), Failure to accelerate, RTD temperature (38, 49), Unbalance (current) (46), Underspeed (14), Starts per hour (66), Phase loss (voltage) (47), Overvoltage (59), Differential (87), Phase loss (current) (46), Undervoltage (27), Phase reverse (voltage) (47), Power factor (55)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 Vac, 25 VA; 80-275 Vdc, 25 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 Vac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePhase current, Earth-leakage current, Phase voltage, 7 digital, tachometer, 1 analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 contacts — See Product Manual \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eAllen-Bradley® DFI and Modbus® RTU (Standard); DeviceNet™, Ethernet (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSurface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOperator Interface Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel, Control-Unit mounted\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA Certified\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eUL Recognized\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(UL 60947-4-1, UL 1053)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403670962470,"sku":"MPS-CTU-01-00","price":6952.38,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/138_27a1afd6-f963-4ed7-ba81-9cd95d0b64e8.jpg?v=1703829152"},{"product_id":"littelfuse-mps-ctu-02-00","title":"Littelfuse MPS-CTU-02-00, MPS Series, Motor Protection System, 65-265VAC\/80-275DC, RS-485 \u0026 DeviceNet","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140418.171.pdf?v=1697522677\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPS Motor Protection System monitors voltage, current, and temperature to provide a comprehensive package of 22 protective functions. The MPS is a modular system with integrated protection, motor control, metering, and data-logging functions. This system is typically used to provide protection for three-phase low- and medium-voltage, medium- to highhorsepower induction motors.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eControl Unit (MPS-CTU)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Current inputs—5-A or 1-A secondary phase current transformers\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Voltage inputs—up to 600 V without PTs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage input—5-A or 1-A secondary or sensitive transformer\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Tachometer (high-speed pulse) input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 8 digital inputs, 5 relay outputs, 1 analog input and output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24-Vdc supply for OPI and RTD modules, and for digital inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• IRIG-B time-code input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/2 DIN size, surface mount\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• RS-485 network communications (Standard)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• DeviceNet™, Profibus®, or Ethernet communications available\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overfrequency (81), Overcurrent (50, 51), Jam, Underfrequency (81), Ground fault (50G\/N, 51G\/N), Undercurrent (37), Unbalance (voltage) (47), Failure to accelerate, RTD temperature (38, 49), Unbalance (current) (46), Underspeed (14), Starts per hour (66), Phase loss (voltage) (47), Overvoltage (59), Differential (87), Phase loss (current) (46), Undervoltage (27), Phase reverse (voltage) (47), Power factor (55)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 Vac, 25 VA; 80-275 Vdc, 25 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 Vac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePhase current, Earth-leakage current, Phase voltage, 7 digital, tachometer, 1 analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 contacts — See Product Manual \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eAllen-Bradley® DFI and Modbus® RTU (Standard); DeviceNet™, Ethernet (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSurface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOperator Interface Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel, Control-Unit mounted\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA Certified\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eUL Recognized\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(UL 60947-4-1, UL 1053)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403675746598,"sku":"MPS-CTU-02-00","price":8616.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/138_ecc2280e-0287-41db-b6a7-2812ae68a336.jpg?v=1703829268"},{"product_id":"littelfuse-mps-ctu-04-00","title":"Littelfuse MPS-CTU-04-00, MPS Series, Motor Protection System, 65-265VAC\/80-275DC, RS-485 \u0026 EtherNet\/IP \u0026 Modbus TCP","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140418.171.pdf?v=1697522677\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MPS Motor Protection System monitors voltage, current, and temperature to provide a comprehensive package of 22 protective functions. The MPS is a modular system with integrated protection, motor control, metering, and data-logging functions. This system is typically used to provide protection for three-phase low- and medium-voltage, medium- to highhorsepower induction motors.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eControl Unit (MPS-CTU)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Current inputs—5-A or 1-A secondary phase current transformers\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Voltage inputs—up to 600 V without PTs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Earth-leakage input—5-A or 1-A secondary or sensitive transformer\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Tachometer (high-speed pulse) input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 8 digital inputs, 5 relay outputs, 1 analog input and output\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 24-Vdc supply for OPI and RTD modules, and for digital inputs\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• IRIG-B time-code input\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• 1\/2 DIN size, surface mount\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• RS-485 network communications (Standard)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• DeviceNet™, Profibus®, or Ethernet communications available\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eProtective Functions (IEEE Device Numbers)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eOverload (49, 51), Phase reverse (current) (46), Overfrequency (81), Overcurrent (50, 51), Jam, Underfrequency (81), Ground fault (50G\/N, 51G\/N), Undercurrent (37), Unbalance (voltage) (47), Failure to accelerate, RTD temperature (38, 49), Unbalance (current) (46), Underspeed (14), Starts per hour (66), Phase loss (voltage) (47), Overvoltage (59), Differential (87), Phase loss (current) (46), Undervoltage (27), Phase reverse (voltage) (47), Power factor (55)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e65-265 Vac, 25 VA; 80-275 Vdc, 25 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003ePower-Up Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e800 ms at 120 Vac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRide-Through Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 ms minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003e24-Vdc Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e100 mA maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eAC Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eTrue RMS and DFT, Peak, 16 samples\/cycle, and positive and negative sequence of fundamental \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e50, 60 Hz or ASD\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePhase current, Earth-leakage current, Phase voltage, 7 digital, tachometer, 1 analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOutput Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e5 contacts — See Product Manual \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eAllen-Bradley® DFI and Modbus® RTU (Standard); DeviceNet™, Ethernet (Optional)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eConformally Coated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eStandard feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eControl Unit Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eSurface\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eOperator Interface Mounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003ePanel, Control-Unit mounted\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eCSA Certified\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(CSA C22.2 No. 14)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\u003cstrong\u003eRCM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 30.9112%;\"\u003e\u003cstrong\u003eUL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 61.0888%;\"\u003e\n\u003cstrong\u003eUL Recognized\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(UL 60947-4-1, UL 1053)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"65-265VAC\/80-275DC","offer_id":47403677942054,"sku":"MPS-CTU-04-00","price":9440.73,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/138_75eecab8-9979-45fb-a5af-8f592c339646.jpg?v=1703829340"},{"product_id":"littelfuse-mp8000","title":"Littelfuse MP8000, MP8000 Series, Motor Protection System, 90–690VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140550.540.pdf?v=1697522765\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe MP8000 series motor protection relay is designed to protect three-phase or single-phase motors with operating voltages of 90-690 V ac (use of external potential transformers can extend upper voltage range above 690 V ac). The MP8000 protects any motor drawing 0.5-1,000 full load amperes (external CTs are required above 100 A). The MP8000 series provides locked rotor, overload, overtemperature, and unbalance protection. Voltage-based protection elements are standard. These relays include inverse time-over current elements suitable for overload protection, and they also provide monitoring functions. The protection is unsurpassed by combining overload, voltage, phase loss and reversal, voltage and current imbalance, power monitoring, and underload in one package.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe relay operates as a fail-safe device. This means when the voltage is within the programmed limits, the relay will energize—the NO contact will close. When the unit loses power or senses a fault condition, the relay will de-energize and contacts will return to their original state. Once the unit has been installed and programmed, it is ready to operate. Once acceptable voltage is applied and the RD0 timer expires, the relay will energize—the NO contact will close.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eBluetooth\/Ethernet Programming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis advanced motor protection electronic overload relay is fully programmable via Bluetooth* using an iPhone or Android smartphone\/tablet with the Littelfuse App. The Bluetooth and Ethernet functions are easy to use, and arc-flash safety is increased because the app allows settings to be modified and real-time operational information viewed. The user is not required to open the control panel for viewing operational information and faults on the app. These relays also feature an Ethernet communications port that can be used to form an Ethernet Modbus TCP\/IP or Ethernet\/IP network. They can be remotely monitored and controlled from a PC, or SCADA system, and data logging through a PC with the optional MP8000 software or other software program using the MP8000 memory map. This capability allows for a simple cost-effective way to further enhance arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Class Trip class 02-60 or linear\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSPST - Form A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSPDT - Form C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Duty Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eB300\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating     -40 °C to 70 °C (-40 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage         -40 °C to 85 °C (-40 °F to 185 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % of reading ±0.5 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±2 % (2 to 100 amperes direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\/-0.5 % of setting +\/- 1second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±5 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (2 to 100 A direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u0026lt;5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3 (conformal coating standard)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque (depluggable terminal blocks)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.5 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque (Earth Ground)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7.9 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(RFI), Conducted\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(RFI), Radiated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFCC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRating Part 15.107 for emissions,\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePart 15.247 for intentional radiators\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Withstand Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA symmetrical at 690 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-Potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size (with insulation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.63”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 74.42 mm (2.93”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 103.63 mm (4.08”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 121.67 mm (4.79”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.85 lbs (13.6 oz, 385.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 60947, UL 1053, C22.2 (File #E68520)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 60947 Edition 5.2, IEC 60947-8\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"90–690VAC","offer_id":47403683152166,"sku":"MP8000","price":1286.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/141._5c49f6dc-8336-4c36-b56a-14cbbe1487de.jpg?v=1703829467"},{"product_id":"littelfuse-77c-kw-hp","title":"Littelfuse 77C-KW\/HP, 77C-KW Series, Single-Phase Current \u0026 Voltage Monitor, 100-240VAC, 1 Phase, 2–90 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140705.963.pdf?v=1697522838\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 77C-KW single-phase relay is part of the 777\/77C product family. The 77C-KW, 77C-KW\/HP and 77C-LR-KW\/HP are fully programmable pump protection relays that monitor for high or low voltage and overload and underload conditions based on power. These overload relays are designed to protect any motor drawing 2–800 full load A (external CTs are required above 90 A). The 777-HVR-SP and 77C are for single-phase 100–240 V ac applications. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e The units also feature a network communications port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus*, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. Common uses include pumping applications where motors run slower than 3400 rpm and usually have small current versus load changes, such as slow speed mixers or agitator motors up to 50 hp, mag-drives, or can pumps.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e Note: The Littelfuse PumpSaver® relay provides the high sensitivity of a power monitor to protect pump motors from dry run and dead head conditions.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 100–240 V ac, 1Ø\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50–60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Full Load Amp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e77C-KW\/HP \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–25 A (loops required); 26–90 A (direct); 91–800 A (external CTs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e77C-LR-KW\/HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.0 A - 2.0 A (additional loop); 2.0 A - 9.0 A (direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Withstand Rating \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA per UL and CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating SPDT (Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating:    480 VA @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose:   10 A @ 240 V ac\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMechanical      1 x 106 operations\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eElectrical          1 x 105 operations at rated load\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy at 25 °C (77 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage            ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent            ±3 % (Direct, No External CTs)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming             5 % ± 1 second\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage            ± 0.5 % of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent            ± 1 % (Direct, No External CTs)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted       IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000 V for 1 min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 78.74 mm (3.1”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 99.06 mm (3.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 129.54 mm (5.1”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePolycarbonate\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.2 lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size Through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65” with insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAmbient Operating   -20 °C–70° C (-4 °F–158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAmbient Storage       -40 °C–80° C (-40 °F–176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20, NEMA 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable Operating Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLV- Low Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e85 V - HV Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHV- High Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e264 V - LV Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMULT- # of Conductors or CT Ratio (XXX:5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e77C:          1–10 Conductors or 100-800 Ratio\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e77C-LR:     1 or 2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOC- Overcurrent Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(20–100 A) ÷ MULT or 80–120 % of CT Primary\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class* \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, J5, 10, J10, 15, J15, 20, J20, 30, J30, or LIn (linear)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD1- Rapid Cycle Timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 2–500 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD2- Restart Delay After All Faults Except Undercurrent (motor cool down timer)**\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–500 minutes\/seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD3- Restart Delay After Undercurrent (dry well recovery timer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–500 minutes\/seconds \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e#RU- Number of Restarts \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAfter Undercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 1, 2, 3, 4, A (Automatic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADDR- RS485 Address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eA01- A99 \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e#RO-Number of Restarts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAfter Overcurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 1, 2, 3, 4, A (Automatic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLP\/PWS (PWS = LP Range) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1 = 0.01 - 0.99 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 2 = 1.00 - 9.95 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 3 = 10.0 - 99.5 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 4 = 100 - 650 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 5 = 0.01 - 1.30 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 6 = 1.34 - 13.3 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 8 = 13.4 - 133 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 9 = 134 - 871 HP\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA      C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"100-240VAC","offer_id":47403731812646,"sku":"77C-KW\/HP","price":748.29,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/77C-kwhp_21b76f41-992e-4556-8951-b643c9ce0044.jpg?v=1703830883"},{"product_id":"littelfuse-77c-lr-kw-hp","title":"Littelfuse 77C-LR-KW\/HP, 77C-KW Series, Single-Phase Current \u0026 Voltage Monitor, 100-240VAC, 1 Phase, 1–9 A (external CTs required above 9 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140705.963.pdf?v=1697522838\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 77C-KW single-phase relay is part of the 777\/77C product family. The 77C-KW, 77C-KW\/HP and 77C-LR-KW\/HP are fully programmable pump protection relays that monitor for high or low voltage and overload and underload conditions based on power. These overload relays are designed to protect any motor drawing 2–800 full load A (external CTs are required above 90 A). The 777-HVR-SP and 77C are for single-phase 100–240 V ac applications. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e The units also feature a network communications port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus*, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. Common uses include pumping applications where motors run slower than 3400 rpm and usually have small current versus load changes, such as slow speed mixers or agitator motors up to 50 hp, mag-drives, or can pumps.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e Note: The Littelfuse PumpSaver® relay provides the high sensitivity of a power monitor to protect pump motors from dry run and dead head conditions.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 100–240 V ac, 1Ø\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50–60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Full Load Amp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e77C-KW\/HP \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–25 A (loops required); 26–90 A (direct); 91–800 A (external CTs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e77C-LR-KW\/HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.0 A - 2.0 A (additional loop); 2.0 A - 9.0 A (direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Withstand Rating \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA per UL and CSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W (Maximum)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating SPDT (Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating:    480 VA @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose:   10 A @ 240 V ac\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpected Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eMechanical      1 x 106 operations\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eElectrical          1 x 105 operations at rated load\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy at 25 °C (77 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage            ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent            ±3 % (Direct, No External CTs)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming             5 % ± 1 second\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage            ± 0.5 % of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent            ± 1 % (Direct, No External CTs)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted       IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000 V for 1 min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 78.74 mm (3.1”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 99.06 mm (3.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 129.54 mm (5.1”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePolycarbonate\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.2 lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size Through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65” with insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eAmbient Operating   -20 °C–70° C (-4 °F–158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAmbient Storage       -40 °C–80° C (-40 °F–176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20, NEMA 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProgrammable Operating Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLV- Low Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e85 V - HV Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHV- High Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e264 V - LV Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMULT- # of Conductors or CT Ratio (XXX:5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e77C:          1–10 Conductors or 100-800 Ratio\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e77C-LR:     1 or 2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOC- Overcurrent Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(20–100 A) ÷ MULT or 80–120 % of CT Primary\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class* \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, J5, 10, J10, 15, J15, 20, J20, 30, J30, or LIn (linear)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD1- Rapid Cycle Timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 2–500 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD2- Restart Delay After All Faults Except Undercurrent (motor cool down timer)**\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–500 minutes\/seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRD3- Restart Delay After Undercurrent (dry well recovery timer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2–500 minutes\/seconds \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e#RU- Number of Restarts \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAfter Undercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 1, 2, 3, 4, A (Automatic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eADDR- RS485 Address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eA01- A99 \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e#RO-Number of Restarts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAfter Overcurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0, 1, 2, 3, 4, A (Automatic)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLP\/PWS (PWS = LP Range) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1 = 0.01 - 0.99 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 2 = 1.00 - 9.95 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 3 = 10.0 - 99.5 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 4 = 100 - 650 KW\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 5 = 0.01 - 1.30 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 6 = 1.34 - 13.3 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 8 = 13.4 - 133 HP\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e 9 = 134 - 871 HP\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA      C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"100-240VAC","offer_id":47403742331174,"sku":"77C-LR-KW\/HP","price":748.29,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/77c-lr-kwhp_e09e6746-8926-4faa-82ef-4330fc05ba36.jpg?v=1703831147"},{"product_id":"littelfuse-77c","title":"Littelfuse 77C, 77C Series, Single-Phase Current \u0026 Voltage Monitor, 100-240VAC, 2-800A (external CTs required above 90A), Provides 480VA @ 240 V ac output SPDT relay contacts","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140917.111.pdf?v=1697522974\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe single-phase 77C unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. The 77C and 777-HVR-SP (family of products) are for single-phase 100-240 V ac applications. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating         480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose         10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models          470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating        -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage            -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage              ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent              ±3 %(\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current        ±15 %\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20 \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted     IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size (with insulation) through 77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL            UL 508, UL 1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE            IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA         C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"100-240VAC","offer_id":47403748000038,"sku":"77C","price":748.29,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/77C-LR_547b709f-fe62-4bb6-bfb9-f49d877d01e6.jpg?v=1703831388"},{"product_id":"littelfuse-77c-lr","title":"Littelfuse 77C-LR, 77C Series, Single-Phase Current \u0026 Voltage Monitor, 100-240VAC, 1-9A only, Provides 480VA @ 240 V ac output SPDT relay contacts","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140917.111.pdf?v=1697522974\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe single-phase 77C unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. The 77C and 777-HVR-SP (family of products) are for single-phase 100-240 V ac applications. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating         480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose         10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models          470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating        -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage            -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage              ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent              ±3 %(\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current        ±15 %\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20 \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted     IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size (with insulation) through 77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL            UL 508, UL 1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE            IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA         C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"100-240VAC","offer_id":47403761697062,"sku":"77C-LR","price":748.29,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/77C-LR_7483948e-6727-4f6e-9893-079b2fabb44d.jpg?v=1703831896"},{"product_id":"littelfuse-777-hvr-sp","title":"Littelfuse 777-HVR-SP, 77C Series, Single-Phase Current \u0026 Voltage Monitor, 100-240VAC, 2-800A (external CTs required above 90A), Provides 470VA @ 600 V ac output SPDT relay contacts. For systems with no control power transformer","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T140917.111.pdf?v=1697522974\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe single-phase 77C unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. The 77C and 777-HVR-SP (family of products) are for single-phase 100-240 V ac applications. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating         480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose         10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models          470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating        -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage            -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage              ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent              ±3 %(\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current        ±15 %\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20 \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted     IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size (with insulation) through 77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL            UL 508, UL 1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE            IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA         C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"340-480VAC","offer_id":47403769430310,"sku":"777-HVR-SP","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-HVR-SP._e53da249-18e2-4abc-9d32-0cd3b0017452.jpg?v=1703832273"},{"product_id":"littelfuse-777-accupower","title":"Littelfuse 777-ACCUPOWER, 777 ACCUPOWER Series, 3-Phase Current \u0026 Voltage Monitor, 190-480VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141043.802.pdf?v=1697523063\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 AccuPower is a fully-programmable, 3-phase motor and pump protection relay. It allows for entry of motor hp rating, full-load amperes, efficiency, and power factors, and will then accurately calculate motor output power. The 777 AccuPower relay is most useful with mag-drive pumps or process applications where the process power is desired over the utility power. Voltage, current, and power measurements can be displayed as well as fault information and setpoints. The built-in display simplifies troubleshooting and allows the user to easily and precisely configure setpoints. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 AccuPower can be used with the optional COM 4-20 output communication module to give an analog signal proportional to output shaft power. Other optional accessories include the RS485MS-2W comms module; the RM1000 remote monitor; and the RM2000 remote monitor. See the accessories products for complete information.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• For use with mag-drive pumps or process applications where the process power is desired over the utility power\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003e\u003cspan data-mce-fragment=\"1\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e200-480 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Full Load Amp Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-800 A (external CTs required over 90 A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2 - 25:     3 phase (looped conductors required)\u003cbr\u003e 25 - 90:   3 phase (direct)\u003cbr\u003e 80 - 800: 3 phase (external CTs)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature) \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty                 480 VA @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral Purpose     10 A @ 240 V ac\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating      -40 °C to 70 °C (-40 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage          -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasured Horsepower\/Kilowatt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eTypical                   ±3 %*\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eVoltage                  ±1 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                  ±3 %(\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current             ±15 %\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    5 % ±1 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5 % of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                    ±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power          10 W\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePollution Degree                       3\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eClass of Protection     IP20, NEMA 1 (finger safe)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRelative Humidity       10-95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTerminal Torque          7 in.-lbs.\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e(ESD) IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted          IEC 61000-4-6, Level 3 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated              IEC 61000-4-3, Level 3 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSurge\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5 Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-Potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL 508 (2 x rated V + 1000 V for 1 min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hrs, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Conductor Size through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65” with insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.3 lbs. (20.8 oz., 589.67 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method Surface mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL             UL 508, UL 1053\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE             IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA          C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"190-480VAC","offer_id":47403777425702,"sku":"777-ACCUPOWER","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-ACCUPOWER_80fc3b37-4426-4ac5-b6f2-1bff12ddf84b.jpg?v=1703832510"},{"product_id":"littelfuse-777-kw-hp-p2","title":"Littelfuse 777-KW\/HP-P2, 777-KW\/HP-P2 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 2-800A (external CTs required above 90A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141159.713.pdf?v=1697523138\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777-KW\/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e *Low current trip and high power trip are network programmable only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC-Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating          480VA @ 240VAC, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose        10A @ 240VAC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR model       470VA @ 600VAC, B600\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating          -20° to 70°C (-4° to 158°F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage              -40° to 80°C (-40° to 176°F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±1%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±3% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±4% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current              ±15%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    ±0.5 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5% of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±1% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±2%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power      10 W\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95%, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6kV contact, 8kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted        IEC 61000-4-6, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”) \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL              UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE              IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA           C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403791483174,"sku":"777-KW\/HP-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777HP-P2._f01313dc-e691-4f4f-b267-191f5d464b2b.jpg?v=1703832757"},{"product_id":"littelfuse-777-lr-kw-hp-p2","title":"Littelfuse 777-LR-KW\/HP-P2, 777-KW\/HP-P2 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 1-800A (external CTs required above 9A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141159.713.pdf?v=1697523138\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777-KW\/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e *Low current trip and high power trip are network programmable only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC-Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating          480VA @ 240VAC, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose        10A @ 240VAC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR model       470VA @ 600VAC, B600\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating          -20° to 70°C (-4° to 158°F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage              -40° to 80°C (-40° to 176°F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±1%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±3% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±4% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current              ±15%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    ±0.5 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5% of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±1% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±2%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power      10 W\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95%, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6kV contact, 8kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted        IEC 61000-4-6, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”) \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL              UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE              IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA           C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403800428838,"sku":"777-LR-KW\/HP-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777HP-P2._f2bb98a5-a336-4805-b5cd-834aa2230b3d.jpg?v=1703833163"},{"product_id":"littelfuse-777-mlr-kw-hp-p2","title":"Littelfuse 777-MLR-KW\/HP-P2, 777-KW\/HP-P2 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 0.5-21A and 40-740A with external CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141159.713.pdf?v=1697523138\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777-KW\/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e *Low current trip and high power trip are network programmable only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003ePre-order 6-8 Weeks\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC-Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating          480VA @ 240VAC, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose        10A @ 240VAC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR model       470VA @ 600VAC, B600\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating          -20° to 70°C (-4° to 158°F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage              -40° to 80°C (-40° to 176°F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±1%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±3% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±4% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current              ±15%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    ±0.5 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5% of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±1% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±2%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power      10 W\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95%, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6kV contact, 8kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted        IEC 61000-4-6, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”) \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL              UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE              IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA           C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403802329382,"sku":"777-MLR-KW\/HP-P2","price":1407.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777HP-P2._6b60bfbc-e177-41c7-b1c2-9f7e65d1e65f.jpg?v=1703833251"},{"product_id":"littelfuse-777-hvr-kw-hp-p2","title":"Littelfuse 777-HVR-KW\/HP-P2, 777-KW\/HP-P2 Series, 3-Phase Current \u0026 Voltage Monitor, 340-480VAC, 2-800A (external CTs required above 90A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141159.713.pdf?v=1697523138\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777-KW\/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e *Low current trip and high power trip are network programmable only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC-Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating          480VA @ 240VAC, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose        10A @ 240VAC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR model       470VA @ 600VAC, B600\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating          -20° to 70°C (-4° to 158°F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage              -40° to 80°C (-40° to 176°F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±1%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±3% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±4% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current              ±15%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    ±0.5 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5% of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±1% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±2%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power      10 W\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95%, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6kV contact, 8kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted        IEC 61000-4-6, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”) \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL              UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE              IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA           C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"340-480VAC","offer_id":47403807572262,"sku":"777-HVR-KW\/HP-P2","price":1407.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777HP-P2._ab2849e5-52af-400c-b999-227eeac41b57.jpg?v=1703833451"},{"product_id":"littelfuse-777-575-kw-hp-p2","title":"Littelfuse 777-575-KW\/HP-P2, 777-KW\/HP-P2 Series, 3-Phase Current \u0026 Voltage Monitor, 500-600VAC, 2-800A (external CTs required above 90A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141159.713.pdf?v=1697523138\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777-KW\/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e *Low current trip and high power trip are network programmable only.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC-Overcurrent Trip Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating          480VA @ 240VAC, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose        10A @ 240VAC\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR model       470VA @ 600VAC, B600\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating          -20° to 70°C (-4° to 158°F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage              -40° to 80°C (-40° to 176°F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±1%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±3% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±4% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGF Current              ±15%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTiming                    ±0.5 second\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eVoltage                   ±0.5% of nominal voltage\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCurrent                   ±1% (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePower                     ±2%\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum Input Power      10 W\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10-95%, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6kV contact, 8kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eConducted        IEC 61000-4-6, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI), \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiated           IEC 61000-4-3, Level 3 10V\/m\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”) \u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL              UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE              IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA           C22.2\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"500-600VAC","offer_id":47403812651302,"sku":"777-575-KW\/HP-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777HP-P2._129455b9-1f32-4208-9b60-715b9c6790d7.jpg?v=1703833602"},{"product_id":"littelfuse-777-mv-p2","title":"Littelfuse 777-MV-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 100-240VAC, 10–800 A with external CTs","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"100-240VAC","offer_id":47403824283942,"sku":"777-MV-P2","price":1308.65,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._5a85f9ae-248c-4eff-8d6a-f3f636b722b1.jpg?v=1703833911"},{"product_id":"littelfuse-777-lr-p2","title":"Littelfuse 777-LR-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 1–800 A (external CTs required above 9 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403844600102,"sku":"777-LR-P2","price":1286.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._98526018-6d80-4bb7-8ce4-24bcc1e44e80.jpg?v=1703834558"},{"product_id":"littelfuse-777-p2","title":"Littelfuse 777-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 2–800 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403851579686,"sku":"777-P2","price":1286.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._78a7ef45-17de-4634-9f26-63e13641622b.jpg?v=1703834776"},{"product_id":"littelfuse-777-lr-ts","title":"Littelfuse 777-LR-TS, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 1–9 A only","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403871600934,"sku":"777-LR-TS","price":1407.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._30eff402-c1d4-490a-b55b-829c2511578b.jpg?v=1703835169"},{"product_id":"littelfuse-777-hrg-p2","title":"Littelfuse 777-HRG-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 2–90 A only","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403883135270,"sku":"777-HRG-P2","price":1407.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._1f5c7411-95b4-40de-8e90-8432a1ad6213.jpg?v=1703835476"},{"product_id":"littelfuse-777-ts","title":"Littelfuse 777-TS, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 2–800 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403890344230,"sku":"777-TS","price":1407.1,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._7f8575ef-760e-4215-b7c7-f55419e72ba5.jpg?v=1703835642"},{"product_id":"littelfuse-777-ft","title":"Littelfuse 777-FT, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 200-480VAC, 2–800 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"200-480VAC","offer_id":47403902959910,"sku":"777-FT","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._9504fb81-b5a9-4dec-b8c0-50631f3be792.jpg?v=1703835948"},{"product_id":"littelfuse-777-hvr-lr-p2","title":"Littelfuse 777-HVR-LR-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 340-480VAC, 1–800 A (external CTs required above 9 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"340-480VAC","offer_id":47403911381286,"sku":"777-HVR-LR-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._e16a0834-7d02-4f2d-852a-e61f388090b7.jpg?v=1703836283"},{"product_id":"littelfuse-777-hvr-p2","title":"Littelfuse 777-HVR-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 340-480VAC, 2–800 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"340-480VAC","offer_id":47403918754086,"sku":"777-HVR-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._77b6d9b4-72f9-4120-822c-8d9e5e0126a8.jpg?v=1703836576"},{"product_id":"littelfuse-777-575-lr-p2","title":"Littelfuse 777-575-LR-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 500-600VAC, 1–800 A (external CTs required above 9 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"500-600VAC","offer_id":47403924947238,"sku":"777-575-LR-P2","price":1286.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._1fa407ab-a336-41d4-8650-48439fbc8d91.jpg?v=1703836738"},{"product_id":"littelfuse-777-575-p2","title":"Littelfuse 777-575-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 500-600VAC, 2–800 A (external CTs required above 90 A)","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"500-600VAC","offer_id":47403933303078,"sku":"777-575-P2","price":1286.57,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._59cbf6dc-de78-4d90-b8ac-9fa24eb75854.jpg?v=1703836927"},{"product_id":"littelfuse-777-575-hrg-p2","title":"Littelfuse 777-575-HRG-P2, 777 Series, 3-Phase Current \u0026 Voltage Monitor, 500-600VAC, 2–90 A only","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141337.414.pdf?v=1697523234\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast \u003c\/strong\u003e\u003cstrong\u003elinear trip is required.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cstrong\u003eAll of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational \u003c\/strong\u003e\u003cstrong\u003einformation, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e*Subtrol and DeviceNet are trademarks of their respective owners\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Conveyor systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• HVAC equipment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Saws and grinders\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Fan motors\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eFunctional Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e02-60, J02-J60, L00-L60 or Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTC- Overcurrent Trip Class (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5, 10, 15, 20, 30 (J prefix enables jam protection feature)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eOutput Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPDT - Form C):\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003ePilot duty rating     480 VA @ 240 V ac, B300\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eGeneral purpose    10 A @ 240 V ac\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePilot duty rating for HVR models    470 VA @ 600 V ac, B600\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOperating    -20 °C to 70 °C (-4 °F to 158 °F)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eStorage        -40 °C to 80 °C (-40 °F to 176 °F)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±3 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGF Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±15 %\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (777 Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming (77C, 777 non-Plus Series units)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 % +1 second\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eRepeatability\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±0.5 % of nominal voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e±1 % (\u0026lt;100 amps direct)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClass of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIP20\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10–95 %, non-condensing per IEC 68-2-3\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e7 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eStandards Passed\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-2, Level 3, 6 kV contact, 8 kV air\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadio Frequency Immunity (RFI),\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eConducted    IEC 61000-4-6, Level 3, 10 V\/m\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRadiated        IEC 61000-4-3, Level 3, 10 V\/m\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast Transient Burst\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 61000-4-4, Level 3, 3.5 kV input power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e100 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eSurge\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eANSI\/IEEE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eC62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHi-potential Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMeets UL508 (2 x rated V +1000 V for 1 minute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Conductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e(with insulation) through 777\/77C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.65”\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 77.47 mm (3.05”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 97.79 mm (3.85”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e D 128.27 mm (5.05”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1.56 lbs. (24.96 oz., 707.6 g)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface mount (4 - #8 screws) or DIN-rail mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003eCertification \u0026amp; Compliance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eUL         UL508, UL1053 (File #E68520)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCSA       C22.2\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCE         IEC 60947-1, IEC 60947-5-1\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"500-600VAC","offer_id":47403936645414,"sku":"777-575-HRG-P2","price":1334.07,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/777-575-HRG-P2.._1d341ac0-6f10-4c5b-a529-a7ebde22a096.jpg?v=1703837038"},{"product_id":"littelfuse-235p","title":"Littelfuse 235P, 235P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase, 5–15 hp","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141502.140.pdf?v=1697523316\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003eThe Littelfuse 235P is designed to protect 5-15 hp, 230 V, single-phase pumps from dry-well, dead-head, jammed impellers, \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003erapid-cycle, and overvoltage and undervoltage conditions. A calibration adjustment allows the 235P to be calibrated to your \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003especific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003eand current-sensing circuit constantly monitors the incoming power for fluctuations causing overcurrent and undercurrent. \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003eWhen an abnormality such as loss of suction is detected, the 235P deactivates its output relay and directly disconnects the \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003epump motor. The 235P communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003edisplays parameters including calibration points, trip points, run time, and last faults. An external current transformer is \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003erequired for operation (sold separately).\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e• Used for single-phase pump protection needs\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e265 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in \u003c\/strong\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–225 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5–15 hp (external current transformer required)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eA300, 720VA @240 V ac (10 Amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 55 °C (-40 °F to 131 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSolid or Stranded 10–22 AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eH 73.66 mm (2.9”)\u003cbr\u003eW 133.35 mm (5.25”) \u003cbr\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus Listed   UL 508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403943428390,"sku":"235P","price":508.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/235P_0bee3406-0340-43fc-97fb-2ea40e9762c0.gif?v=1703837299"},{"product_id":"littelfuse-235p-encl","title":"Littelfuse 235P-ENCL, 235P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase, 233P with NEMA3R enclosure","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141502.140.pdf?v=1697523316\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003eThe Littelfuse 235P is designed to protect 5-15 hp, 230 V, single-phase pumps from dry-well, dead-head, jammed impellers, \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003erapid-cycle, and overvoltage and undervoltage conditions. A calibration adjustment allows the 235P to be calibrated to your \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003especific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003eand current-sensing circuit constantly monitors the incoming power for fluctuations causing overcurrent and undercurrent. \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003eWhen an abnormality such as loss of suction is detected, the 235P deactivates its output relay and directly disconnects the \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003epump motor. The 235P communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003edisplays parameters including calibration points, trip points, run time, and last faults. An external current transformer is \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003erequired for operation (sold separately).\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e• Used for single-phase pump protection needs\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e265 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in \u003c\/strong\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–225 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5–15 hp (external current transformer required)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eA300, 720VA @240 V ac (10 Amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 55 °C (-40 °F to 131 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSolid or Stranded 10–22 AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 in.-lbs\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eH 73.66 mm (2.9”)\u003cbr\u003eW 133.35 mm (5.25”) \u003cbr\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus Listed   UL 508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403946279206,"sku":"235P-ENCL","price":621.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/235P-ENCL_d94e02ec-f257-45d1-af72-d47fc9fe773c.gif?v=1703837445"},{"product_id":"littelfuse-234-p","title":"Littelfuse 234-P, 234-P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase, Load range: 1 ⁄3 to 3 hp","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141653.134.pdf?v=1697523438\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe PumpSaver® Plus Model 234-P protects single-phase pumps from dry-well, dead-head, rapid-cycle, jammed impellers, and over\/undervoltage conditions. Typical applications include residential waterwells, commercial waterwells, irrigation wells, golf courses, and other sprinkler systems. The Model 234-P is designed to be mounted inside a Grundfos* control box** to protect 1 ⁄3 –3 hp, 2- or 3-wire, 230 V pumps. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold separately). \u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003cbr\u003eA calibration adjustment allows the 234-P to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the 234-P deactivates its output relay and directly disconnects the pump motor. The 234-P then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the 234-P reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the 234-P will operate in manual reset mode. \u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e• Residential waterwells\u003cbr\u003e• Commercial waterwells\u003cbr\u003e• Irrigation wells\u003cbr\u003e• Golf courses\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e265 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in \u003c\/strong\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–225 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄3 – 1 hp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3 hp @ 240 V ac (17 Amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 70 °C (-40 °F to 158 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eGrundfos* Control Box\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards Passed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrostatic Discharge (ESD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403955912998,"sku":"234-P","price":552.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/234P_085a3ff1-5b84-4ec7-a3ad-46b365b92997.gif?v=1703837750"},{"product_id":"littelfuse-233p","title":"Littelfuse 233P, 233P Series, Single-Phase Pump Monitor, 230VAC, 1 Phase, Load Range: 1 ⁄3 - 3 hp","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141842.483.pdf?v=1697523541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,overvoltage, and undervoltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the \u003c\/strong\u003e\u003cstrong\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction,is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held diagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Waterwells: residential, commercial, irrigation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Golf course systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAdjustments\/Settings:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e125% of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eAdjustable (70 to 90% of calibrated run power)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e265VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e190VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eNumber of restarts allowed in a 60-sec. period (rapid-cycling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDry-well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOver\/Undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e2 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAll other faults\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eManual, 2-225 Minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e230VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5:   1⁄3 – 1.5 hp\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:          1⁄3 – 3 hp\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e50\/60Hz (Note: 50Hz will increase all delay timers by 20%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5: 1.5 hp @ 240 V ac (10 amps max.)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:        3 hp @ 240 V ac (17 amps max.)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e-40º to 55º C (-40º to 131º F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e14 oz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003ecULus   Listed UL508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403969872166,"sku":"233P","price":508.78,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/233P_059a7199-4b06-475c-ae53-684082f015d9.gif?v=1703838018"},{"product_id":"littelfuse-233p-encl","title":"Littelfuse 233P-ENCL, 233P Series, Single-Phase Pump Monitor, 230VAC, 1 Phase, 233P with NEMA3R enclosure","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141842.483.pdf?v=1697523541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,overvoltage, and undervoltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the \u003c\/strong\u003e\u003cstrong\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction,is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held diagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Waterwells: residential, commercial, irrigation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Golf course systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAdjustments\/Settings:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e125% of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eAdjustable (70 to 90% of calibrated run power)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e265VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e190VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eNumber of restarts allowed in a 60-sec. period (rapid-cycling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDry-well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOver\/Undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e2 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAll other faults\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eManual, 2-225 Minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e230VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5:   1⁄3 – 1.5 hp\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:          1⁄3 – 3 hp\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e50\/60Hz (Note: 50Hz will increase all delay timers by 20%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5: 1.5 hp @ 240 V ac (10 amps max.)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:        3 hp @ 240 V ac (17 amps max.)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e-40º to 55º C (-40º to 131º F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e14 oz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003ecULus   Listed UL508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403974820134,"sku":"233P-ENCL","price":621.84,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/233P-ENCL_4b235166-9b42-4e4d-b167-7ffef7d8a763.gif?v=1703838196"},{"product_id":"littelfuse-233p-1-5","title":"Littelfuse 233P-1.5, 233P Series, Single-Phase Pump Monitor, 230VAC, 1 Phase, Load Range: 1 ⁄3 - 1.5 hp","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141842.483.pdf?v=1697523541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,overvoltage, and undervoltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the \u003c\/strong\u003e\u003cstrong\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction,is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held diagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Waterwells: residential, commercial, irrigation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Golf course systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAdjustments\/Settings:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e125% of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eAdjustable (70 to 90% of calibrated run power)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e265VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e190VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eNumber of restarts allowed in a 60-sec. period (rapid-cycling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDry-well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOver\/Undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e2 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAll other faults\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eManual, 2-225 Minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e230VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5:   1⁄3 – 1.5 hp\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:          1⁄3 – 3 hp\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e50\/60Hz (Note: 50Hz will increase all delay timers by 20%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5: 1.5 hp @ 240 V ac (10 amps max.)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:        3 hp @ 240 V ac (17 amps max.)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e-40º to 55º C (-40º to 131º F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e14 oz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003ecULus   Listed UL508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403981177126,"sku":"233P-1.5","price":396.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/233P-1.5_ebbd35f4-e34a-47a6-a270-4a2f3c1d89eb.gif?v=1703838454"},{"product_id":"littelfuse-233p-1-5-encl","title":"Littelfuse 233P-1.5-ENCL, 233P Series, Single-Phase Pump Monitor, 230VAC, 1 Phase, 233P-1.5 with NEMA3R enclosure","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T141842.483.pdf?v=1697523541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,overvoltage, and undervoltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the \u003c\/strong\u003e\u003cstrong\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction,is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held diagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cstrong\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Waterwells: residential, commercial, irrigation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Golf course systems\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAdjustments\/Settings:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e125% of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eAdjustable (70 to 90% of calibrated run power)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e265VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e190VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eNumber of restarts allowed in a 60-sec. period (rapid-cycling)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDry-well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e4 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOver\/Undervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e2 seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eAll other faults\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eManual, 2-225 Minutes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e230VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5:   1⁄3 – 1.5 hp\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:          1⁄3 – 3 hp\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e50\/60Hz (Note: 50Hz will increase all delay timers by 20%)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003e233P-1.5: 1.5 hp @ 240 V ac (10 amps max.)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e233P:        3 hp @ 240 V ac (17 amps max.)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e-40º to 55º C (-40º to 131º F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e14 oz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 44.7724%;\"\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.2276%;\"\u003e\u003cstrong\u003ecULus   Listed UL508, C22.2 No. 14\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403990974758,"sku":"233P-1.5-ENCL","price":478.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/233P-1.5-ENCL_f9c85d0d-853e-43f8-8b00-72b8e3fa7e34.gif?v=1703838586"},{"product_id":"littelfuse-232-insider","title":"Littelfuse 232-INSIDER, 232-Insider Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T142001.157.pdf?v=1697523614\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe single-phase 232-Insider PumpSaver® fits inside ⅓, ½, ¾, and 1 hp, 230 V Grundfos control boxes. The PumpSaver 232-Insider is designed to protect single-phase pumps from dry-well, dead-head, jammed impellers, overvoltage, and undervoltage conditions. Typical applications include residential water wells, commercial water wells, irrigation wells, and golf course systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA calibration adjustment allows the 232-Insider to be calibrated to your specific pumping application, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality, such as loss of suction is detected, the 232-Insider deactivates its output relay and directly disconnects the pump motor. The 232-Insider then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the 232-Insider reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the 232-Insider will operate in manual reset mode. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer*.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: The use of flow restrictors or unusually high head pressures at the time of calibration may interfere with the detection of dead-head conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*Note: 50 Hz will increase all delay timers by 20 %\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003ePre-order 6-8 Weeks\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 Phase Line Voltage (±10 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e230 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄3–1 hp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50*\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOperating Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of Cal. Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e80 % or 87 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh Voltage Reset Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e265\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow Voltage Reset Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Time (Overload) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 sec.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Time (Dry well) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4 sec.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eRestart Delay Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\/Undervoltage Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 sec\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAll other faults (dry-well rec. timer)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eManual, 2–225 min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating (SPST)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 hp @ 240 V ac (17 amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 Watts (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403995562278,"sku":"232-INSIDER","price":365.02,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/232_99448805-d745-44f9-a011-17522f5738d4.gif?v=1703838832"},{"product_id":"littelfuse-231-insider-p","title":"Littelfuse 231-INSIDER-P, 231-Insider-P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase","description":"\u003cp\u003e\u003cstrong\u003eThe 231-Insider-P monitor fits inside ⅓, ½, ¾, and 1 hp, 230 V control boxes. It is designed to protect single-phase, submersible pumps from dry-well, dead-head, jammed impellers, rapid-cycle, overvoltage, and undervoltage conditions. A calibration adjustment allows the Insider to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the relay will operate in manual reset mode.\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Insider communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults. An IR Kit-12 (12” fiber optic kit) is included with each Insider, allowing the Informer to access these parameters even when the Insider is enclosed in a control box. This is valuable for troubleshooting the pump while it is running.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNOTE: The 231-Insider-P model has a sensitivity adjustment for the dry-well trip point. After calibration is done, you can adjust the sensitivity for the dry-well\/dead-head trip point from 70-90 % of the full load. This makes the unit even more adaptable to varying pumping applications. If you have a very low producing well, increase the sensitivity closer to the 90 % mark, or if you have a very heavy producing well, decrease the sensitivity around the 70 % mark.\u003cbr\u003e\u003cbr\u003eFeatures\u003cbr\u003eProprietary microcontroller-based circuitry\u003cbr\u003eOnboard sensitivity adjustment\u003cbr\u003eAdjustable restart delay\u003cbr\u003eBuilt-in IR communications link\u003cbr\u003eLED indication\u003c\/strong\u003e\u003c\/p\u003e","brand":"Littelfuse","offers":[{"title":"230VAC","offer_id":47403999133990,"sku":"231-INSIDER-P","price":339.18,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/231-Insider_5057e773-e43e-4816-9cc1-a27a7a84100a.gif?v=1703839055"},{"product_id":"littelfuse-111p","title":"Littelfuse 111P, 111P Series, Single-Phase Pump Monitor, Voltage Sensing AC 115VAC, 1 Phase, Load Range: 1 ⁄3 - 1hp","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T142717.160.pdf?v=1697524053\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eDescription\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,\u003cbr data-mce-fragment=\"1\"\u003eovervoltage, and undervoltage conditions.oltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003cbr\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the\u003cbr\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction, is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its\u003cbr\u003euser-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held\u003cbr\u003ediagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points,trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003cbr\u003e• Waterwells: residential, commercial, irrigation\u003cbr\u003e• Golf course systems\u003cbr\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e132.5 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e95 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–225 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e115 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄3 – 1 hp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1hp@120VAC (16 amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 55 °C (-40 °F to 131 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"115VAC","offer_id":47404013322534,"sku":"111P","price":396.83,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/111P_09bd7cc7-9156-4f90-b989-3172b84a198c.gif?v=1703839378"},{"product_id":"littelfuse-111p-encl","title":"Littelfuse 111P-ENCL, 111P Series, Single-Phase Pump Monitor, Voltage Sensing AC 115VAC, 1 Phase, 111P with NEMA3R enclosure","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T142717.160.pdf?v=1697524053\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eDescription\u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Littelfuse models 111P (115 volt, 1⁄3 to 1hp); 233P-1.5 (230 volt, 1⁄3 to 1.5hp); and 233P (230 volt, 1⁄3 to 3hp) are singlephase pump monitors used in a variety of applications to protect from dry-well, dead-head, jammed impeller, rapid-cycling,\u003cbr data-mce-fragment=\"1\"\u003eovervoltage, and undervoltage conditions.oltage conditions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperation\u003cbr\u003eA calibration adjustment allows the unit to be calibrated to your specific pumping applications, which reduces the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitor the\u003cbr\u003eincoming power for fluctuations, overcurrent, and undercurrent conditions. When an abnormality, such as loss of suction, is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its\u003cbr\u003euser-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. The infrared LED communicates with a hand-held\u003cbr\u003ediagnostics tool called the Informer* (sold separately). The Informer displays parameters including calibration points,trip points, run time and last faults.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #ff2a00;\"\u003eApplications\u003c\/span\u003e\u003cbr\u003e• Pumps: submersible, centrifugal, circulating, cooling, environmental\u003cbr\u003e• Waterwells: residential, commercial, irrigation\u003cbr\u003e• Golf course systems\u003cbr\u003e• Sprinkler systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e132.5 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e95 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–225 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e115 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄3 – 1 hp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1hp@120VAC (16 amps max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\" data-mce-style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 55 °C (-40 °F to 131 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Gauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSolid or Stranded 10 - 22AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e13 in.-lbs.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eH 73.66 mm (2.9”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eW 133.35 mm (5.25”)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eD 73.99 mm (2.913”)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e#8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"115VAC","offer_id":47404021055782,"sku":"111P-ENCL","price":478.41,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/111P-ENCL_85531502-7c1c-4a4f-aa04-369b2c995898.gif?v=1703839569"},{"product_id":"littelfuse-111-insider-p","title":"Littelfuse 111-INSIDER-P, 111-Insider-P Series, Single-Phase Pump Monitor, Voltage Sensing AC 115VAC, 1 Phase, 1 ⁄3–1 hp includes IR Kit-12","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/media_-_2023-10-17T142847.987.pdf?v=1697524146\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cstrong\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13_480x480.png?v=1695188636\"\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe single-phase 111-Insider-P monitor fits inside 1⁄3 and 1⁄2 hp, 115 V control boxes. It is designed to protect single-phase, submersible pumps from dry-well, dead-head, jammed impellers, rapid-cycle, overvoltage, and undervoltage conditions. A calibration adjustment allows the Insider to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the relay will operate in manual reset mode.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Insider communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults. An IR Kit-12 (12” fiber optic kit) is included with each Insider, allowing the Informer to access these parameters even when the Insider is enclosed in a control box. This is valuable for troubleshooting the pump while it is running.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eFunctional Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\/Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvercurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125 % of calibration point\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnderload (dry-well)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable (70 to 90 % of calibrated run power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOvervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e132.5 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUndervoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e95 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNumber of restarts allowed in\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ea 60-sec. period (rapid-cycling)\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOvercurrent    5 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eDry-well          4 seconds\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRestart Delay Times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eOver\/Undervoltage        2 seconds\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAll other faults                Manual, 2–25 minutes\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e115 V ac\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄3–1 ⁄2 hp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e50\/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Contact Rating-SPST\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e1 ⁄2 hp @ 120 V ac (17 A max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #ff2a00;\"\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 °C to 55 °C (-40 °F to 131 °F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5 W\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10 oz.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eInside a Pentek*, Franklin*, CentriPro*, Grundfos* (mfg after mid-2014), Flowise Pro,* and Flint and Walling* control box\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification \u0026amp; Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ecURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Littelfuse","offers":[{"title":"115VAC","offer_id":47404024725798,"sku":"111-INSIDER-P","price":339.18,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/111-Insider-P_0c59f413-4c8c-4929-b8b9-fc05d775390e.gif?v=1703839798"}],"url":"https:\/\/auroraindustry.com\/collections\/motor-and-pump-protection-relays.oembed?page=9","provider":"AuroraIndustry.com","version":"1.0","type":"link"}