{"title":"Motor Protection Controls","description":null,"products":[{"product_id":"alltemp-24-icm102","title":"Alltemp 24-ICM102, Delay on Make Timer, 18-240 VAC, 50\/60 Hz, Adjustable Delay 0.03-10 Minutes","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges. When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eUniversal voltage operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigher 1.5 amp power rating\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eKnob-adjustable time delays\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWorks with anticipator-type thermostats\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOne model replaces many in field\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSimple 2-wire hookup\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e18-240 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e1.5 amps, 15 amp inrush, 40 mA holding current\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e0.03-10 Minutes (1.8-600 Seconds)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.5 V @ 1.5 amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.00'' x 2.00'' x 1.25''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53846979707174,"sku":"24-ICM102","price":64.8,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM102.jpg?v=1789001658"},{"product_id":"alltemp-24-icm103","title":"Alltemp 24-ICM103, Delay on Make Timer, 18-240 VAC, 50\/60 Hz, Switch Settable Time Delay 1-1023 Seconds","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges. When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHighly precise digital timing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSwitch-settable time delays\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIdeal for ice machine applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUniversal voltage operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRepeat accuracy .5% over voltage and temperature range\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e18-240 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e1.0 amp, 10 amp inrus, 40 mA holding current\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e1-1,023 seconds, switch settable in 1-second increments\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.5 V @ 1 amp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.00'' x 2.00'' x 1.25''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53847004381478,"sku":"24-ICM103","price":82.72,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM103.jpg?v=1789003798"},{"product_id":"alltemp-24-icm104","title":"Alltemp 24-ICM104, Delay on Make Timer, 18-30 VAC, 50\/60 Hz, SPDT Output, Knob-Adjustable Time Delay 10-1000 Seconds","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges. When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHighly precise digital circuitry\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigh power, SPDT relay output\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInput to output isolation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWorks with anticipator-type thermostats\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRepeat accuracy .5% over voltage and temperature range\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRugged, compact package\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e18-30 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eSPDT 1 Form C\u003cbr\u003eN.O.: 20 amps @ 240 VAC\u003cbr\u003eN.C.: 10 amps @ 240 VAC\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eMotor Load Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e@ 120VAC: N.O., 2 HP, N.C., 1\/2 HP\u003cbr\u003e@ 240VAC: N.O., 2 HP, N.C., 1\/2 HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e10-1,000 Seconds Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.5 V @ 1 amp\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.00'' x 3.00'' x 1.25''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-30VAC","offer_id":53847028498726,"sku":"24-ICM104","price":150.64,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM104.jpg?v=1789004252"},{"product_id":"alltemp-24-icm203","title":"Alltemp 24-ICM203, Delay On Break Timer, 18-240 VAC, 50\/60 Hz, Adjustable Delay 0.03-10 Minutes","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges. When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eUniversal voltage operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHigher 1.5 amp power rating\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompressor lockout\/anti-short cycle timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHelps to protect compressors from damage caused by rapid short cycling\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSimple, 2-wire hookup\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e18-240 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e1.5 amps, 15 amp inrush, 40 mA holding current\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e0.03-10 Minutes (1.8-600 Seconds)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e3.5 V typical, 4.5 V max. @ 1.5 amps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.00'' x 2.00'' x 1.25''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53847058186534,"sku":"24-ICM203","price":63.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM203.jpg?v=1789005170"},{"product_id":"alltemp-24-icm175","title":"Alltemp 24-ICM175, Bypass Timer, 18-240 VAC, 50\/60 Hz, Knob-Adjustable Time Delay 10-1000 Seconds","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned to bypass a control or device during startup. Typically used to bypass a low pressure switch during compressor heat pump startup or to bypass an oil pressure switch upon startup. Helps to eliminate nuisance lockouts. With power applied to the input, the load energizes immediately and remains energized for the length of the time delay, regardless of the state of the switch being bypassed. At the end of the time delay, the condition of the load is determined by the state of the switch.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eDesigned to bypass a low pressure switch or other device during startup\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eKey component for “winter start” kits\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUniversal AC voltage operation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eKnob-adjustable time delay\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEpoxy-encapsulated circuitry\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 137.157px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e18-240 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e1 amps, 10 amp inrush, 40 mA holding current\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eTime Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e10-1,000 Seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e2.00'' x 2.00'' x 1.25''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53847074832678,"sku":"24-ICM175","price":66.7,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM175.jpg?v=1789005804"},{"product_id":"alltemp-24-icm450a","title":"Alltemp 24-ICM450A, Motor Protection Control, Programmable 3-Phase Line Voltage Monitor, Universal 190-600 VAC, 50\/60 Hz, Control 18-240 VAC, SPDT Output","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eBacklit LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSimultaneous 3-phase true RMS voltage monitoring\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFactory calibrated\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3-phase voltages simultaneously displayed on LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault monitoring: High \/ low voltage, voltage unbalance, phase loss, phase reversal\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReal time clock, date and time stamped events (ICM450A PLUS+ Only)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFully adjustable variables\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModbus RS485 communications (ICM450A PLUS+ Only)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLED indicators\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommon 1\/4'' quick connect terminations\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnglish or Spanish menu options\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 156.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eUniversal 190-600 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eLoad Side Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eOptional\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003e18-240 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRelay, SPDT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003e277 VAC @ 6A maximum\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003eSurface mount using (2) #8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e1\/4'' quick connects\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e6.50'' x 4.75'' x 1.09''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e-4ºF to +149ºF (-20ºC to +65ºC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53847403168038,"sku":"24-ICM450A","price":718.28,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM450A.jpg?v=1789007540"},{"product_id":"alltemp-24-icm450a-plus","title":"Alltemp 24-ICM450A-PLUS, Motor Protection Control, Programmable 3-Phase Line Voltage Monitor, Modbus RS485 Communications, Real Time Clock, Date and Time Stamped Events","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eBacklit LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSimultaneous 3-phase true RMS voltage monitoring\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFactory calibrated\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3-phase voltages simultaneously displayed on LCD\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault monitoring: High \/ low voltage, voltage unbalance, phase loss, phase reversal\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eReal time clock, date and time stamped events (ICM450A PLUS+ Only)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFully adjustable variables\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModbus RS485 communications (ICM450A PLUS+ Only)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLED indicators\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCommon 1\/4'' quick connect terminations\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEnglish or Spanish menu options\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 156.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eUniversal 190-600 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eLoad Side Monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eOptional\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003e18-240 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003eRelay, SPDT\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e\u003cspan\u003e277 VAC @ 6A maximum\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003eSurface mount using (2) #8 screws\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e1\/4'' quick connects\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e6.50'' x 4.75'' x 1.09''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40.7871%;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%;\"\u003e\u003cstrong\u003e-4ºF to +149ºF (-20ºC to +65ºC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-240VAC","offer_id":53847416897830,"sku":"24-ICM450A-PLUS","price":776.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM450A-PLUS.jpg?v=1789007540"},{"product_id":"alltemp-24-icm401a","title":"Alltemp 24-ICM401A, 3-Phase Motor Protection Control, Universal 180-600 VAC, 50\/60 Hz, Control 18-32 VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-161.pdf?v=1789009097\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLow cost 3-phase protection for single side\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMonitors for phase reversal, phase loss, unbalance % as a function of input voltage\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBright LED indicators for ON and FAULT\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEpoxy-encapsulated for moisture protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePatented: U.S. Patent No. 5,337,206\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 156.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eUniversal 180-600 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz (Jumper Wire Cut: 50 Hz)\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e18-32 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eN.O.: 6 amps @ 32 VAC max\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e3.00'' x 3.25'' x 1.00''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"18-32VAC","offer_id":53847424598310,"sku":"24-ICM401A","price":163.28,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM401A.jpg?v=1789009089"},{"product_id":"alltemp-24-icm402","title":"Alltemp 24-ICM402, 3-Phase Motor Protection Control, Universal 190-600 VAC, 50\/60 Hz, Control 115 or 208\/230 VAC, SPST Relay Output","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-161.pdf?v=1789009097\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLow cost 3-phase protection for single side\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMonitors for phase reversal, phase loss, unbalance % as a function of input voltage\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBright LED indicators for ON and FAULT\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHighly reliable passive electronics\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEpoxy-encapsulated for moisture protection\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePatented: U.S. Patent No. 5,337,206\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 156.75px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eUniversal 190-600 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eControl Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e115 or 208\/230 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eRelay, SPST, N.O. 30 amps\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003e3.00'' x 3.20'' x 1.35''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 40.7871%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.8551%; height: 19.5938px;\"\u003e\u003cstrong\u003eCSA, cURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"115\/208\/230VAC","offer_id":53847437213990,"sku":"24-ICM402","price":280.68,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM402.jpg?v=1789010327"},{"product_id":"alltemp-24-icm493","title":"Alltemp 24-ICM493, Single Phase Line Monitor with Built-In Surge Suppression, Input 180-264 VAC, 50\/60 Hz, Anti-Short Cycle Delay 0.5-10 Minutes","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-163.pdf?v=1789010975\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe ICM493 is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against lightning strikes. Includes a built-in 40A contactor. Housed in a NEMA Rated 3R enclosure for outdoor installations. UL Listed. Installs easily between the service disconnect and the condensing unit. Ideal for Mini-Splits or other valuable, single-phase equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProtects against over and under voltage, rapid short cycling caused by transients, and high-power surges\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault history feature records and retains the five most recently occurred faults in non-volatile memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIdeal for mini-splits or other condensing units\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEasy to view, backlit digital display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBank of five L-L surge arresters\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Line Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e180-264 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e+\/- 2%, User Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eContactor; 2-Pole\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eContactor Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e40A FLA, 240A LRA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Setpoint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e200-240 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eOver\/Under Voltage Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e 5% - 10%, Adjustable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAnti-Short Cycle Delay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.5-10 Minutes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Surge Arresters Required for Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0-5\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Retries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e1-5, Auto\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003eNEMA Rated 3R Outdoor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e8'' x 8.25'' x 4.3''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"180-264VAC","offer_id":53847448224038,"sku":"24-ICM493","price":1115.46,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM493.jpg?v=1789010970"},{"product_id":"alltemp-24-icm493-60a","title":"Alltemp 24-ICM493-60A, Single Phase Line Monitor with Built-In Surge Suppression, Input 195-264 VAC, 50\/60 Hz, 60A Contactor","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-163.pdf?v=1789010975\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe ICM493-60A is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against lightning strikes. Includes a built-in 60A contactor to support larger systems. Housed in a NEMA Rated 3R enclosure for outdoor installations. UL Listed. Installs easily between the service disconnect and the condensing unit. Ideal for Mini-Splits or other valuable, single-phase equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProtects against over and under voltage, rapid short cycling caused by transients, and high-power surges\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault history feature records and retains the five most recently occurred faults in non-volatile memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIdeal for mini-splits or other condensing units\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEasy to view, backlit digital display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBank of five L-L surge arresters\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 313.501px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Line Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e195-264 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e+\/- 2%, User Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eContactor; 2-Pole\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eContactor Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e240 VAC, 60A FLA, 360A LRA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Setpoint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e200-240 VAC Adjustable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAnti-Short Cycle Delay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.5-10 Minutes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Surge Arresters Required for Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0-5\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Retries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e1-5, Auto\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003eFour mounting holes in back of enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 39.1875px;\"\u003e\u003cstrong\u003eWeather resistant, NEMA 3R rated for outdoor installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e8'' x 10'' x 6''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003e-40°F to 167°F (-40°C to 75°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6995%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 47.9428%; height: 19.5938px;\"\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"195-264VAC","offer_id":53847466639654,"sku":"24-ICM493-60A","price":1141.74,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM493-60A.jpg?v=1789012236"}],"url":"https:\/\/auroraindustry.com\/collections\/motor-protection-controls.oembed","provider":"AuroraIndustry.com","version":"1.0","type":"link"}