{"product_id":"alltemp-24-icm493","title":"Alltemp 24-ICM493, Single Phase Line Monitor with Built-In Surge Suppression, Input 180-264 VAC, 50\/60 Hz, Anti-Short Cycle Delay 0.5-10 Minutes","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-160.pdf?v=1789007643\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-163.pdf?v=1789010975\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe ICM493 is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against lightning strikes. Includes a built-in 40A contactor. Housed in a NEMA Rated 3R enclosure for outdoor installations. UL Listed. Installs easily between the service disconnect and the condensing unit. Ideal for Mini-Splits or other valuable, single-phase equipment.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eProtects against over and under voltage, rapid short cycling caused by transients, and high-power surges\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFault history feature records and retains the five most recently occurred faults in non-volatile memory\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIdeal for mini-splits or other condensing units\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEasy to view, backlit digital display\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBank of five L-L surge arresters\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 274.313px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Line Voltage\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e180-264 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e50\/60 Hz\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e+\/- 2%, User Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eContactor; 2-Pole\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eContactor Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e40A FLA, 240A LRA\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Setpoint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e200-240 VAC\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eOver\/Under Voltage Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e 5% - 10%, Adjustable\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eAnti-Short Cycle Delay\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0.5-10 Minutes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Surge Arresters Required for Operation\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 39.1875px;\"\u003e\u003cstrong\u003e\u003cspan\u003e0-5\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNumber of Retries\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003e1-5, Auto\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003eNEMA Rated 3R Outdoor Enclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003e8'' x 8.25'' x 4.3''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 51.6349%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 48.0073%; height: 19.5938px;\"\u003e\u003cstrong\u003ecULus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"180-264VAC","offer_id":53847448224038,"sku":"24-ICM493","price":1115.46,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM493.jpg?v=1789010970","url":"https:\/\/auroraindustry.com\/products\/alltemp-24-icm493","provider":"AuroraIndustry.com","version":"1.0","type":"link"}