{"product_id":"alltemp-24-umsr50-umsr-50","title":"Alltemp 24-UMSR50, UMSR-50, Universal Motor Starting Relay, Voltage Sensing, Single Phase, 110-270 VAC","description":"\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Control_Transformer.pdf?v=1788850049\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Thermostats-PRO.pdf?v=1788940599\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Delay_On_Make_Timers.pdf?v=1789001675\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Surge_Protectors-166.pdf?v=1789021534\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-167.pdf?v=1789023712\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-170.pdf?v=1789029506\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/Miniature_Pressure_Control_Switches-169.pdf?v=1789089707\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/ICM_ControlsElectrical-173.pdf?v=1789096316\" target=\"_blank\" rel=\"noopener\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/13.png?v=1695188636\" alt=\"\"\u003e\u003c\/a\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eReplacement for all standard potential relays\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePatented differential voltage sensing\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNo user-adjustments required \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNon-positional mounting configuration\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e50A switching capabilities\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eUniversal mounting bracket for easy installation\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e0.250” quick connect termination\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSafety timer\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 224.5px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003e110-270 VAC, single phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum Voltage Contact Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003e502 VAC (absolute)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003e\u003cspan\u003eMotor Power Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003eUp to 10 HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003e\u003cspan\u003eOperating Position\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003eNon-Positiona\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Time Out\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003eApproximately 1-second per 100 microfarads\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003eConsumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003e5 VA maximum\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9219px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 19.9219px;\"\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 19.9219px;\"\u003e\u003cstrong\u003eClass B (130°C); Conforms to IEC 1000- standards (6kV impulse \/ 6kV contact)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003e50A (break only)\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.7188px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.7188px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.7188px;\"\u003e\u003cstrong\u003e2.00'' x 2.00'' x 1.75''\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.8281px;\"\u003e\n\u003ctd style=\"width: 45.444%; height: 22.8281px;\"\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.1982%; height: 22.8281px;\"\u003e\u003cstrong\u003ecURus\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Alltemp","offers":[{"title":"110-270VAC","offer_id":53852470772006,"sku":"UMSR-50","price":101.74,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/4088\/9126\/files\/24-UMSR50.jpg?v=1789096304","url":"https:\/\/auroraindustry.com\/products\/alltemp-24-umsr50-umsr-50","provider":"AuroraIndustry.com","version":"1.0","type":"link"}