Intermatic GM40AV-QW, 7-Day and Auto-voltage General Purpose Time Control, Type 3R outdoor enclosure w/Battery Backup, DPDT, 40A, 120-277V
FOR ALL ORDERS OUTSIDE CANADA, CUSTOMERS ARE RESPONSIBLE FOR ANY IMPORT DUTIES, TARIFFS, TAXES, AND CUSTOMS FEES THAT MAY APPLY TO THEIR ORDERS.
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The GM40AV Time Switch is a universal, electromechanical time switch designed for general purpose residential and commercial applications. The robust 40 A time switch automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120-277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time switch features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts).
- Auto-voltage selection 120 VAC-277 VAC.
- Captive trippers - trippers cannot be lost.
- 40 A rating.
- Self-recharging battery backup, "Q" models feature 72-hour carry-over.
- Power and status LED indicators.
- 24-Hour or 7-day models available.
- Up to 48 ON/OFF operations per 24-hour period or 42 ON/OFF operations per week on "W" models.
- DPDT switching configuration standard (2 NO and 2 NC Contacts).
- Manual three-way ON/OFF/AUTO override switch.
-
Easy-to-read clock face.
| Model Number | GM40AV-QW |
| Description | 40 A, Auto-voltage General Purpose Time Control |
| Color | Gray |
| Minimum ON/OFF Times | 2 hours |
| Maximum ON/OFF Times | 2 hours |
| Operation Mode | 7 day |
| Backup Type | 72-hour Carry-over; Battery; Self-recharging |
| Backup Protection Time | 72 Hours |
| Battery Service Type | Non-Replaceable |
| Mechanism Type | Electromechanical |
| Chemical Composition of the Battery Cell | Ni-MH |
| Enclosure Type | Indoor/outdoor type 3R plastic |
| Magnetic Ballast (NO) Range(s) | 30 A, 120 VAC; 20 A, 277 VAC |
| Magnetic Ballast (NC) Range(s) | 10 A, 277 VAC |
| Resistive (NO) Range(s) | 40 A, 120-277 VAC |
| Resistive (NC) Range(s) | 30 A, 120-277 VAC |
| Pilot Duty (NO) Range(s) | 300 VA, 120-240 VAC |
| Motor Load (NC) Range(s) | 1 HP, 12 FLA, 30 LRA @ 120 VAC; 2 HP, 10 FLA, 30 LRA @ 240 VAC |
| Motor Load (NO) Range(s) | 1 HP, 16 FLA, 90 LRA @120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC |
| Tungsten Incandescent (NC) Range(s) | 2 A, 120 VAC |
| Tungsten Incandescent (NO) Range(s) | 15 A, 120 VAC |
| Voltage Selection Type | Auto-Voltage |
| Wiring Option | Screw box lug |
| Input Voltage Range(s) | 120-277 VAC, 50/60 Hz |
| Switch Type | DPDT |
| Power consumption (V) | 1 VA |
| Electrical Life | 50,000 operations at full load |
| Operating Humidity | 0-95% RH, Non-condensing |
| Temperature (operation) | -40 °F to 131 °F / (-40 °C to 55 °C) |
| UL Certification | cULus |
| RoHS Certification | N/A |
| Warranty Period | 1-Year limited |