Littelfuse 234-P, 234-P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase, Load range: 1 ⁄3 to 3 hp
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The PumpSaver® Plus Model 234-P protects single-phase pumps from dry-well, dead-head, rapid-cycle, jammed impellers, and over/undervoltage conditions. Typical applications include residential waterwells, commercial waterwells, irrigation wells, golf courses, and other sprinkler systems. The Model 234-P is designed to be mounted inside a Grundfos* control box** to protect 1 ⁄3 –3 hp, 2- or 3-wire, 230 V pumps. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold separately).
Operation
A calibration adjustment allows the 234-P to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the 234-P deactivates its output relay and directly disconnects the pump motor. The 234-P then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the 234-P reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the 234-P will operate in manual reset mode.
Applications
• Residential waterwells
• Commercial waterwells
• Irrigation wells
• Golf courses
Pre-order 6-8 Weeks
Specifications
Functional Specifications | |
Adjustments/Settings | |
Overcurrent | 125 % of calibration point |
Underload (dry-well) | Adjustable (70 to 90 % of calibrated run power |
Overvoltage | 265 V ac |
Undervoltage | 190 V ac |
Number of restarts allowed in a 60-sec. period (rapid-cycling) | 4 |
Trip Delay Times |
Overcurrent 5 seconds Dry-well 4 seconds |
Restart Delay Times |
Over/Undervoltage 2 seconds All other faults Manual, 2–225 minutes |
Input Characteristics | |
Supply Voltage | 230 V ac |
Load Range | 1 ⁄3 – 1 hp |
Frequency | 50/60 Hz (Note: 50 Hz will increase all delay timers by 20 %) |
Output Characteristics | |
Output Contact Rating-SPST | 3 hp @ 240 V ac (17 Amps max.) |
General Characteristics | |
Operating Temperature | -40 °C to 70 °C (-40 °F to 158 °F) |
Maximum Input Power | 5 W (max.) |
Weight | 14 oz. |
Mounting Methods | Grundfos* Control Box |
Standards Passed | Electrostatic Discharge (ESD) |