Littelfuse 234-P, 234-P Series, Single-Phase Pump Monitor, Voltage Sensing AC 230VAC, 1 Phase, Load range: 1 ⁄3 to 3 hp

In stock
SKU: 234-P
Regular price $552.78
Rated voltage

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The PumpSaver® Plus Model 234-P protects single-phase pumps from dry-well, dead-head, rapid-cycle, jammed impellers, and over/undervoltage conditions. Typical applications include residential waterwells, commercial waterwells, irrigation wells, golf courses, and other sprinkler systems. The Model 234-P is designed to be mounted inside a Grundfos* control box** to protect 1 ⁄3 –3 hp, 2- or 3-wire, 230 V pumps. An infrared LED communicates directly with a hand-held diagnostic tool called the Informer (sold separately).

Operation
A calibration adjustment allows the 234-P to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the 234-P deactivates its output relay and directly disconnects the pump motor. The 234-P then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the 234-P reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the 234-P will operate in manual reset mode.

Applications
• Residential waterwells
• Commercial waterwells
• Irrigation wells
• Golf courses

Pre-order 6-8 Weeks

Specifications

Functional Specifications  
Adjustments/Settings
Overcurrent 125 % of calibration point
Underload (dry-well) Adjustable (70 to 90 % of calibrated run power
Overvoltage 265 V ac
Undervoltage 190 V ac
Number of restarts allowed in a 60-sec. period (rapid-cycling) 4
Trip Delay Times Overcurrent    5 seconds
Dry-well          4 seconds
Restart Delay Times Over/Undervoltage        2 seconds
All other faults                Manual, 2–225 minutes
Input Characteristics
Supply Voltage 230 V ac
Load Range 1 ⁄3 – 1 hp
Frequency 50/60 Hz (Note: 50 Hz will increase all delay timers by 20 %)
Output Characteristics
Output Contact Rating-SPST 3 hp @ 240 V ac (17 Amps max.)
General Characteristics
Operating Temperature -40 °C to 70 °C (-40 °F to 158 °F)
Maximum Input Power 5 W (max.)
Weight 14 oz.
Mounting Methods Grundfos* Control Box
Standards Passed Electrostatic Discharge (ESD)