Littelfuse 35040026, 350 Series, 3-phase voltage/phase monitor, Voltage Asymmetry, Voltage Sensing AC 380 ~ 480VAC, DPDT (2 Form C)

In stock
SKU: 35040026
Regular price $458.19
Rated voltage
Phase
Description

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The 350 series is a heavy-duty voltage monitor. This product should be used when high current relays or dual contacts are required, or 480 V controls are used. Since the 350 series uses heavy-duty relays, it comes in fixed voltage range models rather than a dual auto-ranging version like the model 250.

The 350200 has a 15 A general purpose contact. The 350400 provides a SPDT (Form C) relay rated to switch up to 600 V, allowing the use of 480 V controls, eliminating the need for a control power transformer to step the voltage down to 120–240 V. Several DPDT (two Form C contacts) relay models are also available. The 350 microcontroller-based family of products are low cost yet highly advanced solutions to heavy-duty problems.

The 350 includes advanced single LED diagnostics. Five different light patterns distinguish faults and normal operating conditions. Other options such as high voltage trip and adjustable restart delay are available.

Features
Proprietary microcontroller-based circuitry
Adjustable restart delay (-2 models) settings
Advanced LED indication
600 V rated relay contacts available on some models

*Note: 50 Hz will increase all delay timers by 20 %

 Specifications

Input Characteristics  
Line Voltage 350200:   190–240 V ac
350400:   380–480 V ac
350600:   475–600 V ac
Frequency 50*/60 Hz
Functional Characteristics
Low Voltage (% of setpoint) Trip            90 %
Reset         93 %
Voltage Unbalance (NEMA) Trip            6 %
Reset         4.5 %
Trip Delay Time: Low Voltage                               4 seconds
Unbalance & Phasing Faults      2 seconds
Restart Delay Time After a Fault                                2 seconds
After a Complete Power Loss     2 seconds
Output Characteristics
Output Contact Rating SPDT (350200)
SPDT (350200) Pilot Duty                 480 VA @ 240 V ac
General Purpose      15 A
SPDT (350-400, 350-600) 470 VA @ 600 V ac
DPDT (-6 Option) 1–10 A General Purpose
480 VA @ 240 V ac Pilot Duty
1–15 A General Purpose
480 VA @ 240 V ac Pilot Duty
1 hp @ 240 V ac
DPDT (-8 Option) 2–15 A General Purpose
480 VA @ 240 V ac Pilot Duty
1 hp @ 240 V ac
General Characteristics
Ambient Temperature Range Operating    -40° to 70°C (-40° to 158°F)
Storage        -40° to 80°C (-40° to 176°F)
Trip & Reset Accuracy ±1 %
Maximum Input Power 5W
Terminal Torque       7 in.-lbs.
Wire Size   12–18 AW
Transient Protection (Internal)  IEC 61000-4-5; 1995 ±6 kV
Safety Marks UL            UL 508 (File #E68520)
CSA          22.2 No. 14 (File #46510)
Dimensions H 74.42 mm (2.93”)
W 133.86 mm (5.27”)
D 74.93 mm (2.95”)
Weight 1.05 lbs. (16.8 oz., 476
Mounting Method #8 screws
Special Options Opt. 2: Variable Restart Delay Manual, 2–300 seconds adj.
Opt. 5: DPDT Relay
Opt. 6: 2 Relays (1) 10 A, (1) 15 A
Opt. 8: 2 Relays (2) 15 A
Opt. 9: High Voltage
(% of setpoint) Trip       110 %
Reset    107 %