Littelfuse 50R-100, 50R Series, Single-Phase Voltage Monitor, Voltage Sensing AC 95 ~ 120VAC, SPDT (1 Form C)
FOR ALL ORDERS OUTSIDE CANADA, CUSTOMERS ARE RESPONSIBLE FOR ANY IMPORT DUTIES, TARIFFS, TAXES, AND CUSTOMS FEES THAT MAY APPLY TO THEIR ORDERS.
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The 50R series is a single-phase voltage monitor with a voltage-sensing circuit that constantly monitors the single-phase power for a low-voltage condition. When a harmful condition is detected, the MotorSaver® deactivates its output relay after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions. This monitor is used in a variety of applications such as compressors, air conditioners, heat pumps, well pumps, sump pumps, and small conveyer motors.
Applications
• Fan motors
• Air conditioners
• Compressors
• Heat, well, and sump pumps
• Small conveyer motors
*Note: 50 Hz will increase all delay timers by 20%
Pre-order 6-8 Weeks
Specifications
| Input Characteristics | |
| Line Voltage |
50R-100 95–120 V ac 50R200 190–240 V ac 50R400 380–480 V ac |
| Frequency | 50*/60 Hz |
| Functional Characteristics | |
| Low Voltage |
Trip (% of setpoint) 90% Reset (% of setpoint) 93% |
| Delay Time (Nominal) Trip | 4 seconds |
| Restart (low voltage) | 2 seconds |
| Restart (complete power loss) | 2 seconds |
| Output Characteristics | |
| Output Contact Rating (SPDT - 1 Form C) | |
| 50R-100, 50R200 |
Pilot Duty 480 VA @ 240 V ac General Purpose 10 A @ 240 V ac |
| 50R400 | Pilot Duty 470 VA @ 600 V ac |
| General Characteristics | |
| Ambient Temperature Range |
Operating -20°C to 70 °C (-4 °F to 158 °F) Storage -40 °C to 80 °C (-40 °F to 176 °F) |
| Maximum Input Power | 5 W |
| Relative Humidity | 10–95%, non-condensing per IEC 68-2-3 |
| Terminal Torque | 7 in.-lbs. |
| Wire Size | 12–18AWG |
| Electrostatic Discharge (ESD) | IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air |
| Fast Transient Burst | IEC 61000-4-4, Level 3, 3.5 kV input power and controls |
| Transient Protection (Internal) | IEC 61000-4-5; 1995 ±6 kV |
| Dimensions |
H 74.4 mm (2.93”) W 133.9 mm (5.27”) D 74.9 mm (2.95”) |
| Weight | 0.98 lb. (15.68 oz., 444.52 g) |
| Mounting Method | #8 screws |
| Special Options | |
| Opt. 2: Variable Restart Delay | Manual, 2–300 seconds |
| Opt. 3: Variable Trip Delay | 2–30 seconds |
| Opt. 9: High Voltage Detection | |
| Operating Points |
Trip (% of Setpoint) 110% Reset (% of Setpoint) 107% |
| Certification & Compliance |
UL UL 508 (File #E68520) CE IEC 60947-6-2 |