Littelfuse 50R-100-2, 50R Series, Single-Phase Voltage Monitor, Voltage Sensing AC 95 ~ 120VAC, SPDT (1 Form C)

In stock
SKU: 50R-100-2
Regular price $350.32
Rated voltage
Phase
Description
⚠️ IMPORT NOTICE
FOR ALL ORDERS OUTSIDE CANADA, CUSTOMERS ARE RESPONSIBLE FOR ANY IMPORT DUTIES, TARIFFS, TAXES, AND CUSTOMS FEES THAT MAY APPLY TO THEIR ORDERS.

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The 50R series is a single-phase voltage monitor with a voltage-sensing circuit that constantly monitors the single-phase power for a low-voltage condition. When a harmful condition is detected, the MotorSaver® deactivates its output relay after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions. This monitor is used in a variety of applications such as compressors, air conditioners, heat pumps, well pumps, sump pumps, and small conveyer motors.

Applications
• Fan motors
• Air conditioners
• Compressors
• Heat, well, and sump pumps
• Small conveyer motors

*Note: 50 Hz will increase all delay timers by 20%

Pre-order 6-8 Weeks

Specifications

Input Characteristics
Line Voltage 50R-100         95–120 V ac
50R200          190–240 V ac
50R400          380–480 V ac
Frequency 50*/60 Hz
Functional Characteristics
Low Voltage Trip (% of setpoint)        90%
Reset (% of setpoint)     93%
Delay Time (Nominal) Trip 4 seconds
Restart (low voltage) 2 seconds
Restart (complete power loss) 2 seconds
Output Characteristics
Output Contact Rating (SPDT - 1 Form C)
50R-100, 50R200 Pilot Duty                  480 VA @ 240 V ac
General Purpose       10 A @ 240 V ac
50R400 Pilot Duty                  470 VA @ 600 V ac
General Characteristics
Ambient Temperature Range Operating     -20°C to 70 °C (-4 °F to 158 °F)
Storage         -40 °C to 80 °C (-40 °F to 176 °F)
Maximum Input Power 5 W
Relative Humidity 10–95%, non-condensing per IEC 68-2-3
Terminal Torque 7 in.-lbs.
Wire Size 12–18AWG
Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air
Fast Transient Burst IEC 61000-4-4, Level 3, 3.5 kV input power and controls
Transient Protection (Internal) IEC 61000-4-5; 1995 ±6 kV
Dimensions H 74.4 mm (2.93”)
W 133.9 mm (5.27”)
D 74.9 mm (2.95”)
Weight 0.98 lb. (15.68 oz., 444.52 g)
Mounting Method #8 screws
Special Options
Opt. 2: Variable Restart Delay Manual, 2–300 seconds
Opt. 3: Variable Trip Delay 2–30 seconds
Opt. 9: High Voltage Detection
Operating Points Trip (% of Setpoint)         110%
Reset (% of Setpoint)      107%
Certification & Compliance UL           UL 508 (File #E68520)
CE           IEC 60947-6-2