Littelfuse 601-CS-D-P1, 601-CS-D-P1 Series, Ground Fault Sensing AC 200 ~ 480VAC, SPDT (1 Form C)

In stock
SKU: 601-CS-D-P1
Regular price $1,515.99
Rated voltage
Phase
⚠️ IMPORT NOTICE
FOR ALL ORDERS OUTSIDE CANADA, CUSTOMERS ARE RESPONSIBLE FOR ANY IMPORT DUTIES, TARIFFS, TAXES, AND CUSTOMS FEES THAT MAY APPLY TO THEIR ORDERS.

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The 601-CS-D-P1 series is a fully programmable, electronic, three-phase, power monitor designed to monitor three-phase systems. This unit has a single relay that can be configured as a general purpose network output or to trip on ground faults. The 601-CS-D-P1 monitors ground-fault current, phase currents, phase voltages, power factor, and frequency. The RS485MS-2W communications module allows the 601-CS-D-P1 to communicate using the Modbus RTU protocol. The Modbus connection can be used to monitor power parameters, set up the device or control the fault relay. A DeviceNet* communications I/O module (CIO-601CS-DN-P1) is also available. This CIO module only works with the 601-CS-D-P1 unit.It is used for sending the information from the 601-CS-D-P1 over a DeviceNet* network. It also provides I/O capabilities and the ability to set the parameters of the 601-CS-D-P1.


The 601-CS-D-P1 includes a built-in display that offers a visual indication for programming and viewing real-time parameters for nominal voltage, voltage unbalance, current, current unbalance, ground-fault warning, ground-fault trip, and ground-fault motor acceleration.

Note: This product must be used with an external zero-sequence CT (not included) for proper operation.

Pre-order 6-8 Weeks

Applications
• For monitoring a zero-sequence current transformer for ground-fault protection

Specifications

Input Characteristics  
Line Voltage 200–480 V ac
Frequency 50/60 Hz
Motor Full Load Amp Range 0.5–175 A (direct) 176–800 A (CTs required)
Input Ground Fault Current 0.5–10 A
Functional Characteristics
Output Contact Rating (SPDT) Pilot Duty 480 VA @ 240 V ac
General Purpose 10 A @ 240 V ac
Expected Life Mechanical       1 x 10⁶ operations
Electrical           1 x 10⁵ operations at rated load
General Characteristics
Ambient Temperature Range Operating     -20° to 70 °C (-4° to 158 °F)
Storage         -40° to 80 °C (-40° to 176 °F)
Accuracy at 25 °C (77 °F) Voltage           +/-1%
Current           +/-3% (<175 A direct)
GF Current      +/-3%
Repeatability
Voltage +/-0.5% of nominal voltage
Current +/-1% (<175 A direct)
Maximum Input Power 10 W
Pollution Degree 3
Class of Protection IP20
Relative Humidity 10–95%, non-condensing per IEC 68-2-3
Terminal Torque 7in.-lbs.
Standards Passed
Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air
Radio Frequency Immunity Conducted              IEC 61000-4-6, Level 3 10 V
Radio Frequency Immunity, Radiated    IEC 61000-4-3, Level 3, 10 V/m
Fast Transient Burst IEC 61000-4-4, Level 3, 3.5 kV input power
Short Circuit Rating 100 kA rms, SYM, 600 V ac max.
Surge
Immunity IEC IEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground
ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line
High Potential Test Meets UL508 (2 x rated V +1000V for 1 minute)
Max Conductor Size (with insulation) 0.65”
Dimensions H 77.47 mm (3.05”)
W 97.79 mm (3.85”)
D 128.27 mm (5.05”)
Weight 1.2 lbs. (19.2 oz., 544.31 g)
Mounting Method Surface mount (4 - #8 screws) or DIN-rail mount
Certification & Compliance UL       UL508 (File #E68520)
CE       IEC 60947-1, IEC 60947-5-1