Littelfuse 777-KW/HP-P2, 777-KW/HP-P2 Series, 3-Phase Current & Voltage Monitor, 200-480VAC, 2-800A (external CTs required above 90A)

In stock
SKU: 777-KW/HP-P2
Regular price $1,334.07
Rated voltage

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The 777-KW/HP-P2 is a 3-phase current and voltage monitor that provides unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring*, and underload trip based on power into one efficient unit. The underpower trip feature is desirable anytime the current vs. load characteristic is non-linear or has little change. In general terms, smaller motors and slow-speed motors have little change in current over the normal load range. Larger motors that are running light loads will also show small current changes over the operating load range. The low and high power protection feature increases reliability for non-linear motors where the load characteristic has little change.

For standalone applications, these units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet**, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software.

*Low current trip and high power trip are network programmable only.

Applications
• Conveyor systems
• HVAC equipment
• Saws and grinders
• Fan motors

Specifications

Frequency  50/60Hz
Functional Characteristics
TC-Overcurrent Trip Class 02-60, J02-J60, L00-L60 or OFF
Output Characteristics
Output Contact Rating (SPDT - Form C): Pilot duty rating          480VA @ 240VAC, B300
General purpose        10A @ 240VAC
Pilot duty rating for HVR model       470VA @ 600VAC, B600
General Characteristics
Ambient Temperature Range: Operating          -20° to 70°C (-4° to 158°F)
Storage              -40° to 80°C (-40° to 176°F)
Accuracy: Voltage                   ±1%
Current                   ±3% (<100 amps direct)
Power                     ±4% (<100 amps direct)
GF Current              ±15%
Timing                    ±0.5 second
Repeatability: Voltage                   ±0.5% of nominal voltage
Current                   ±1% (<100 amps direct)
Power                     ±2%
Maximum Input Power      10 W
Pollution Degree 3
Class of Protection IP20
Relative Humidity 10-95%, non-condensing per IEC 68-2-3
Terminal Torque 7 in.-lbs.
Standards Passed
Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity (RFI), Conducted        IEC 61000-4-6, Level 3 10V/m
Radio Frequency Immunity (RFI), Radiated           IEC 61000-4-3, Level 3 10V/m
Fast Transient Burst IEC 61000-4-4, Level 3, 3.5 kV input power
Short Circuit Rating 100kA
Surge
IEC 61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground
ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line
Hi-potential Test Meets UL508 (2 x rated V +1000V for 1 minute)
Vibration IEC 68-2-6, 10-55Hz, 1mm peak-to-peak, 2 hours, 3 axis
Shock IEC 68-2-27, 30g, 3 axis, 11ms duration, half-sine pulse
Maximum Conductor Size
(with insulation) through 777 0.65”
Dimensions H 77.47 mm (3.05”)
W 97.79 mm (3.85”)
D 128.27 mm (5.05”)
Weight 1.56 lbs. (24.96 oz., 707.6 g)
Mounting Method Surface mount (4 - #8 screws) or DIN rail mount
Certification & Compliance UL              UL508, UL1053 (File #E68520)
CE              IEC 60947-1, IEC 60947-5-1
CSA           C22.2