Littelfuse 777-MV-P2, 777 Series, 3-Phase Current & Voltage Monitor, 100-240VAC, 10–800 A with external CTs

In stock
SKU: 777-MV-P2
Regular price $1,308.65
Rated voltage

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The 777 unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). The 777 (family of products) is used for 3-phase, 200-480 V ac applications, with several specialized units for other voltage ranges and unique applications. Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. Some unique applications include use with a Subtrol* equipped Franklin submersible motor to detect high motor temperatures and applications where a fast linear trip is required.
All of the overload relays provide unsurpassed protection by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload based on current — all in one package. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. The units also feature a communications network port that can be used with communication modules listed in the 777 accessories section to form a Modbus, DeviceNet*, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.

*Subtrol and DeviceNet are trademarks of their respective owners

Applications
• Conveyor systems
• HVAC equipment
• Saws and grinders
• Fan motors

Specifications

Functional Characteristics  
Frequency 50/60 Hz
TC- Overcurrent Trip Class (777 Plus Series units) 02-60, J02-J60, L00-L60 or Off
TC- Overcurrent Trip Class (77C, 777 non-Plus Series units) 5, 10, 15, 20, 30 (J prefix enables jam protection feature)
Output Characteristics
Output Contact Rating (SPDT - Form C): Pilot duty rating     480 VA @ 240 V ac, B300
General purpose    10 A @ 240 V ac
Pilot duty rating for HVR models    470 VA @ 600 V ac, B600
General Characteristics
Ambient Temperature Range: Operating    -20 °C to 70 °C (-4 °F to 158 °F)
Storage        -40 °C to 80 °C (-40 °F to 176 °F)
Accuracy
Voltage ±1 %
Current ±3 % (<100 amps direct)
GF Current ±15 %
Timing (777 Plus Series units) ±0.5 second
Timing (77C, 777 non-Plus Series units) 5 % +1 second
Repeatability
Voltage ±0.5 % of nominal voltage
Current ±1 % (<100 amps direct)
Maximum Input Power 10 W
Pollution Degree 3
Class of Protection IP20
Relative Humidity 10–95 %, non-condensing per IEC 68-2-3
Terminal Torque 7 in.-lbs
Standards Passed
Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air
Radio Frequency Immunity (RFI), Conducted    IEC 61000-4-6, Level 3, 10 V/m
Radiated        IEC 61000-4-3, Level 3, 10 V/m
Fast Transient Burst IEC 61000-4-4, Level 3, 3.5 kV input power
Short Circuit 100 kA
Surge
IEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground
ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line
Hi-potential Test Meets UL508 (2 x rated V +1000 V for 1 minute)
Vibration IEC 68-2-6, 10–55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis
Shock IEC 68-2-27, 30g, 3 axis, 11 ms duration, half-sine pulse
Maximum Conductor Size
(with insulation) through 777/77C 0.65”
Dimensions H 77.47 mm (3.05”)
W 97.79 mm (3.85”)
D 128.27 mm (5.05”)
Weight 1.56 lbs. (24.96 oz., 707.6 g)
Mounting Method Surface mount (4 - #8 screws) or DIN-rail mount
Certification & Compliance UL         UL508, UL1053 (File #E68520)
CSA       C22.2
CE         IEC 60947-1, IEC 60947-5-1