Littelfuse 77C-LR, 77C Series, Single-Phase Current & Voltage Monitor, 100-240VAC, 1-9A only, Provides 480VA @ 240 V ac output SPDT relay contacts

In stock
SKU: 77C-LR
Regular price $748.29
Rated voltage
 More payment options

Pickup available at 220 Alden Road

Usually ready in 24 hours

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The single-phase 77C unit is a fully-programmable, electronic overload relay designed to protect any motor drawing 2-800 full load A (external CTs are required above 90 A). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application. The 77C and 777-HVR-SP (family of products) are for single-phase 100-240 V ac applications.

All of the overload relays provide unsurpassed protection by combining overload, underload, and voltage in one unit. For standalone applications, the units incorporate a 3-digit LED display that is used for programming, providing real-time operational information, and displaying diagnostic codes to aid in troubleshooting a fault condition. These units also feature a communications network port that can be used with communication modules, listed in the 777 accessories section, to form a Modbus, DeviceNet™, Profibus, or Ethernet network. Up to 99 units can be remotely monitored and controlled from a PC, PLC, or SCADA system, and data logging through a PC with the optional Solutions software. This capability allows for a simple, cost-effective way to meet new requirements for arc-flash safety.

Applications
• Conveyor systems
• HVAC equipment
• Saws and grinders
• Fan motors

Pre-order 6-8 Weeks

Specifications

Functional Characteristics  
Frequency 50/60 Hz
TC- Overcurrent Trip Class (77C, 777 non-Plus Series units) 5, 10, 15, 20, 30 (J prefix enables jam protection feature)
Output Characteristics
Output Contact Rating (SPDT - Form C) Pilot duty rating         480 VA @ 240 V ac, B300
General purpose         10 A @ 240 V ac
Pilot duty rating for HVR models          470 VA @ 600 V ac, B600
General Characteristics
Ambient Temperature Range Operating        -20 °C to 70 °C (-4 °F to 158 °F)
Storage            -40 °C to 80 °C (-40 °F to 176 °F)
Accuracy Voltage              ±1 %
Current              ±3 %(<100 amps direct)
GF Current        ±15 %
Timing (77C, 777 non-Plus Series units) 5 % +1 second
Repeatability
Voltage ±0.5 % of nominal voltage
Current ±1 % (<100 amps direct)
Maximum Input Power 10 W
Pollution Degree 3
Class of Protection IP20
Relative Humidity 10-95 %, non-condensing per IEC 68-2-3
Terminal Torque 7 in.-lbs
Standards Passed
Electrostatic Discharge (ESD) IEC 61000-4-2, Level 3, 6 kV contact, 8 kV air
Radio Frequency Immunity (RFI) Conducted     IEC 61000-4-6, Level 3 10 V/m
Radiated        IEC 61000-4-3, Level 3 10 V/m
Fast Transient Burst IEC 61000-4-4, Level 3, 3.5 kV input power
Short Circuit 100 kA
Surge
IEC 61000-4-5, Level 3, 2 kV line-to-line; Level 4, 4 kV line-to-ground
ANSI/IEEE C62.41 Surge and Ring Wave Compliance to a level of 6 kV line-to-line
Hi-potential Test Meets UL 508 (2 x rated V +1000V for 1 minute)
Vibration IEC 68-2-6, 10-55 Hz, 1 mm peak-to-peak, 2 hours, 3 axis
Shock IEC 68-2-27, 30 g, 3 axis, 11 ms duration, half-sine pulse
Maximum Conductor Size (with insulation) through 77C 0.65”
Dimensions H 77.47 mm (3.05”)
W 97.79 mm (3.85”)
D 128.27 mm (5.05”)
Weight 1.56 lbs. (24.96 oz., 707.6 g)
Mounting Method Surface mount (4 - #8 screws) or DIN rail mount
Certification & Compliance UL            UL 508, UL 1053 (File #E68520)
CE            IEC 60947-1, IEC 60947-5-1
CSA         C22.2