Littelfuse ECSW6MBHT, ECSW Series, Current Sensors, Current Sensing AC 230VAC, SPDT (1 Form C)
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The ECSW Series of single-phase, AC window, current sensors includes adjustable overcurrent and undercurrent trip points. Detects locked rotor, jam, loss of load, an open heater or lamp load, a broken belt, or loss of suction. LED’s aid in trip point adjustment and provide fault indication. The built-in toroidal sensor eliminates the need for an external current transformer. The output can be electrically latched after a fault, or automatically reset. Remote resetting of a latched output by removing input voltage. The unit includes switch selectable zero current detection and normally de-energized or energized output operation. Time delays are included to improve operation and eliminate nuisance tripping
Features & Benefits
Built-in toroidal current sensing | Eliminates need to install stand alone current transformer and provides isolation from monitored circuit |
Encapsulated | Protects against shock, vibration, and humidity |
LED indication | Visual indication for trip point adjustment and fault indication |
Multiple switch selectable features | User selectable zero current detection, latched, normally de-energized, or energized output adds application flexibility |
Adjustable trip delay | Eliminates nuisance tripping and prevents rapid cycling |
Isolated 10A, SPDT output contacts | Allows control of loads for AC or DC voltages |
Specifications
Sensor | |
Type | Toroid, through hole wiring for up to #4 AWG (21.1 mm2 ) THHN wire |
Mode | Over & undercurrent trip points (window current sensing) |
Trip Point Range | 0.5 - 50A in 3 adjustable ranges |
Tolerance | Guaranteed range |
Maximum Allowable Current | Steady - 50A turns; Inrush - 300A turns for 10s |
Time Point vs Temp. & Voltage | ±5% |
Response Time | ≤ 75ms |
Frequency | 45/500 Hz |
Type of Detection | Peak detection |
Zero Current Detection | < 250mA turns typical |
Trip Delay | |
Range | 0.15 - 50s in 2 adjustable ranges or 0.1 - 50s fixed |
Tolerance | Adjustable: guaranteed range; Fixed: ±10% |
Sensing Delay On Start Up | Fixed ≅ 0.1 - 6s in 1s increments |
Tolerance | +40% -0% |
Delay vs. Temp. & Voltage | ±15% |
Input | |
Voltage | 24, 120, or 230VAC; 12 or 24VDC |
Tolerance |
12VDC & 24VDC/AC: -15% - 20% 120 & 230VAC: -20% - 10% |
AC Line Frequency | 50/60 Hz |
Output | |
Type | Electromechanical relay |
Mode: Switch Selectable |
ON: Energized during normal operation, de-energized after a fault OFF: De-energized during normal operation, energizes during a fault |
Form | Isolated, SPDT |
Rating |
10A resistive @ 240VAC; 1/4 hp @ 125VAC; 1/2 hp @ 250VAC |
Life | Mechanical - 1 x 106 ; Electrical - 1 x 105 |
Type | Electrical |
Reset | Remove input voltage |
Function | Switch selectable latching function |
Protection | |
Surge | IEEE C62.41-1991 Level A |
Circuitry | Encapsulated |
Isolation Voltage | ≥ 2500V RMS input to output |
Insulation Resistance | ≥ 100 MΩ |
Mechanical | |
Mounting | Surface mount with two #6 (M3.5 x 0.6) screws |
Dimensions |
H 88.9 mm (3.5”); W 63.5 mm (2.5”); D 44.5 mm (1.75”) |
Termination |
0.197 in. (5 mm) terminal blocks for up to #12 (3.2 mm2) AWG wire |
Environmental | |
Operating/Storage Temperature | -40° to 60°C / -40° to 85°C |
Humidity | 95% relative, non-condensing |
Weight | ≅ 6.4 oz (181 g) |