Littelfuse FS143, FS100 Series(Medium Amp), Flashers and Tower Lighting Control, 24VAC, 90 FPM Flash Rate
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The FS100 Series (medium power) may be used to control inductive, incandescent, or resistive loads. Input voltages of 24, 120, or 230VAC are available. Fixed flash rates in stock range from 30, 50, 60, and 90 FPM, with custom flash rates ranging from 10 to 300 FPM. Encapsulation provides protection against shock, vibration, and humidity. This group of solid-state flashers has proven reliability with years of use throughout the world.
Operation
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed.
Reset: Removing input voltage resets the output and the sequence to T2.
Pre-order 6-8 Weeks
Technical Data | |
Operation | OFF/ON solid-state flasher (continuous duty) |
Flash Rate | Fixed at 90 FPM ±10% |
Custom Flash Rates Available | 10 - 300 FPM ±10% |
ON/OFF Ratio | ≅ 50% |
Input | |
Voltage | ±15% / 50/60 Hz |
Output | |
Output | Fullwave AC, solid state, SPST |
Load Type | Inductive, resistive, or incandescent |
Maximum Load Rating | 3A steady state |
Inrush | 10 times steady state current |
Mechanical | |
Mounting | Surface mount with one #10 (M5 x 0.8) screw |
Dimensions |
H 50.8 mm (2”); W 50.8 mm (2”); D 30.7 mm (1.21”) |
Termination | 0.25 in. (6 .35 mm) male quick connect terminals |
Protection | |
Circuitry | Encapsulated |
Environmental | |
Operating/Storage Temperature | -20° to 60°C / -40° to 85°C |
Weight | ≅ 2.2 oz (62 g) |