Littelfuse HRDS321, HRDS Series, 24VDC, One Shot Time Delay Relay SPDT (1 Form C) 1 Sec ~ 100 Sec Delay 30A @ 125/240VAC Chassis Mount
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The HRDS Series combines an electromechanical relay output with microcontroller timing circuitry. It offers 12 to 230V operation in five options and factory fixed, onboard or external adjustable time delays with a repeat accuracy of ±0.5%. The output contact rating allows for direct operation of heavy loads, such as compressors, pumps, blower motors, heaters, etc. This series is ideal for OEM applications where cost is a factor.
Operation (Single Shot)
Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch, the output relay energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output will energize if the initiate switch is closed when input voltage is applied.
Reset: Reset occurs when the time delay is complete and the initiate switch is opened. Loss of input voltage resets the time delay and output.
Pre-order 6-8 Weeks
Specifications
Time Delay | |
Type | Microcontroller circuitry |
Range | 0.1s - 100m in 5 adjustable ranges or fixed |
Repeat Accuracy | ±0.5% or 20ms, whichever is greater |
Tolerance (Factory Calibration) | ±1%, ±5% |
Reset Time | ≤ 150ms |
Time Delay vs Temp. & Voltage | ≤ 20ms |
Input | |
Voltage | 12 or 24VDC; 24, 120, or 230VAC |
Tolerance |
12VDC & 24VDC -15% - 20% 24 to 230VAC -20% - 10% |
AC Line Frequency | 50/60 Hz |
Power Consumption | AC ≤ 4VA; DC ≤ 2W |
Output | |
Type | Electromechanical relay |
Form | SPDT, non-isolated |
Ratings | SPDT-NO SPDT-NC |
General Purpose | 125/240VAC 30A 15A |
Resistive |
125/240VAC 30A 15A 28VDC 20A 10A |
Motor Load |
125VAC 1 hp* 1/4 hp** 240VAC 2 hp** 1 hp** |
Life |
Mechanical - 1 x 10⁶ Electrical - 1 x 10⁵, *3 x 10⁴, **6,000 |
Protection | |
Surge | IEEE C62.41-1991 Level A |
Circuitry | Encapsulated |
Dielectric Breakdown | ≥ 2000V RMS terminals to mounting surface |
Insulation Resistance | ≥ 100 MΩ |
Polarity | DC units are reverse polarity protected |
Mechanical | |
Mounting | Surface mount with one #10 (M5 x 0.8) screw |
Dimensions |
H 76.7 mm (3”) W 51.3 mm (2”) D 38.1 mm (1.5”) |
Termination | 0.25 in. (6.35 mm) male quick connect terminals |
Environmental | |
Operating/Storage Temperature | -40° to 60°C / -40° to 85°C |
Humidity | 95% relative, non-condensing |
Weight | ≅ 3.9 oz (111 g) |