Littelfuse HRISW27I, HRIS Series, 24-240VAC/24-110DC, Interval Time Delay Relay SPDT (1 Form C) 0.1 Hrs ~ 10 Hrs Delay 30A @ 125/240VAC Chassis Mount
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The HRPS/HRIS Series combines an electromechanical relay output with microcontroller timing circuitry. It is a factory programmed module available in any 1 of 13 standard functions. It offers 12 to 240V operation in two universal ranges and factory fixed, onboard, or external adjustable time delays with a repeat accuracy of ±0.5%. The output contact rating allows for direct operation of heavy loads, such as compressors, pumps, blower motors, heaters, etc. This series is ideal for OEM applications where cost is a factor. The HRPS has non-isolated SPDT relay contacts, and the HRIS has isolated SPDT relay contacts. Both offer the most popular timer functions in the industry
Operation (Interval)
Upon application of input voltage, the time delay begins. The output (relay or solid state) energizes during the time delay. At the end of time delay the output de-energizes and remains de-energized until input voltage is removed.
Reset: Removing input voltage resets the time delay and output.
Pre-order 6-8 Weeks
Specifications
Time Delay | |
Type | Microcontroller circuitry |
Range | 0.1s - 1000h in 9 adjustable ranges or fixed |
Repeat Accuracy | ±0.5% or 20ms, whichever is greater |
Tolerance (Factory Calibration) | ±2% |
Reset Time | ≤ 150ms |
Time Delay vs Temp. & Voltage | ±2% |
Initiate Time | ≤ 20ms |
Input | |
Voltage | 12 to 48VDC; 24 to 240VAC/24 to 110VDC |
Tolerance |
12 to 48VDC -15% - 20% 24 to 110VDC/240VAC -20% - 10% |
AC Line Frequency | 50/60 Hz |
Power Consumption | AC ≤ 4VA; DC ≤ 2W |
Output | |
Type | Electromechanical relay |
Form | SPDT |
Ratings | SPDT-NO SPDT-NC |
General Purpose | 125/240VAC 30A 15A |
Resistive |
125/240VAC 30A 15A 28VDC 20A 10A |
Motor Load |
125VAC 1 hp* 1/4 hp** 240VAC 2 hp** 1 hp** |
Life |
Mechanical - 1 x 10⁶ Electrical - 1 x 10⁵, *3 x 10⁴, **6,000 |
Protection | |
Surge | IEEE C62.41-1991 Level A |
Circuitry | Encapsulated |
Dielectric Breakdown | ≥ 1500V RMS input to output; isolated units |
Insulation Resistance | ≥ 100 MΩ |
Polarity | DC units are reverse polarity protected |
Mechanical | |
Mounting | Surface mount with one #10 (M5 x 0.8) screw |
Dimensions |
H 76.2 mm (3.0”) W 50.8 mm (2.0”) D 38.1 mm (1.5”) |
Termination | 0.25 in. (6.35 mm) male quick connects |
Environmental | |
Operating/Storage Temperature | -40° to 60°C / -40° to 85°C |
Humidity | 95% relative, non-condensing |
Weight | ≅ 3.9 oz (111 g) |