Littelfuse HRV11SC, HRV Series, 12VDC, Programmable (Multi-Function) Time Delay Relay SPDT (1 Form C) 1 Sec ~ 127 Sec Delay 30A @ 125/240VAC Chassis Mount

In stock
SKU: HRV11SC
Regular price $247.62
Rated voltage
Mode of operation
Rating

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The HRV combines the accuracy of microcontroller based circuitry with an electromechanical relay output. The HRV’s switching capacity allows direct control of loads like compressors, pumps, motors, heaters, and lighting. The HRV “S” version provides a vend time after the selected number of initiate switch closures to start is reached. The HRV “A” version includes all of the “S” features and allows the total vend time to be extended for each additional initiate switch closure. The HRV is ideal for cost sensitive single coin or token vending machines. The electronic circuitry is encapsulated to protect against humidity and vibration.

Operation 

Coin Totalizer & Vending Timer (“S” Version): Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time set on the upper 7 DIP switches begins. At the end of the vending time, the load de-energizes and the vending time is reset. Closing the initiate switch during vend timing will have no affect on vend time delay.

Accumulating Vending Timer (“A” Version): Input voltage must be applied prior to and during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time starts. For every initiate switch closure, the HRV unit adds one time per coin period, as set on the upper 7 DIP switches, to the total vending time

Reset: Removing input voltage resets the vend time delay, the S1 closure counter, and de-energizes the output relay.

Pre-order 6-8 Weeks

Specifications

Count Functions/ Switch Type  Mechanical (counts on switch closure)
Closure Time ≥ 20ms
Minimum Switch Open (between closures) Time ≥ 20ms
Count Range to Start 1 - 7 counts
Maximum Counts (“A” Version) 250
Time Delay/Range *** Adjustable 1s - 31.75m in 4 ranges
Adjustment 7 of a 10 position DIP switch
Setting Accuracy 0% to +2% or 50ms, whichever is greater
Repeat Accuracy ±0.1% or 20ms, whichever is greater
Reset Time ≤ 150ms
Time Delay vs Temp. & Voltage ≤ ±2%
Input
Voltage 12 or 24VDC; 24, 120, or 230VAC
Tolerance 12VDC & 24VDC/AC             -15% - 20%
120 & 230 VAC                      -20% - 10%
AC Line Frequency/DC Ripple 50/60 Hz / ≤ 10%
Power Consumption AC ≤ 4VA; DC ≤ 2W
Output
Type Electromechanical relay
Form Isolated, SPDT or non-isolated, SPDT
Ratings                               SPDT-NO            SPDT-NC
General Purpose 125/240VAC             30A                    15A
Resistive 125/240VAC             30A                    15A
28VDC                        20A                    10A
Motor Load 125VAC                    1 hp*                  1/4 hp**
240VAC                    2 hp**                  1 hp**
Life Mechanical - 1 x 10⁶
Electrical - 1 x 10⁵, *3 x 10⁴, **6,000
Protection
Surge IEEE C62.41-1991 Level A
Circuitry Encapsulated
Dielectric Breakdown ≥ 1500V RMS input to output; isolated units
Insulation Resistance ≥ 100 MΩ
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Dimensions H 76.7 mm (3”)
W 50.8 mm (2”)
D 38.1 mm (1.5”)
Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage Temperature -40° to 70°C / -40° to 85°C
Humidity 95% relative, non-condensing
Weight ≅ 3.9 oz (111 g)