Littelfuse ISS-102CCI-M-MC, ISS-102 Series, Two-Channel Intrinsically Safe Switch, 120VAC, DPDT (2 Form C)
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The ISS-102 is a two-channel, intrinsically-safe switch designed for multiple uses including a pump-up/pump-down (latching) controller or two-channel switch. LEDs indicate the state of the intrinsically-safe inputs and output relays and user-selectable options are available including a variable resistance threshold for float inputs. The ISS-102 enclosure is surface or DIN rail mountable
-LC Each input channel is active when the corresponding switch is closed. When the lag input (CH2) is activated, the output closes. Applying latching logic, the output contact remains closed until the lead (CH1) and the lag (CH2) inputs are deactivated. Sensitivity is fixed at 100kOhms with a debounce time delay of 2 seconds.
-DCS This dual-channel switch has two Form A output relays. Two LEDs illuminate the output state of their respective Form A relay. Resistance probes or switches can be used on its inputs. Sensitivity is fixed at 100kOhms with a debounce time delay of 0.5 seconds.
-MC By selecting the proper functionality through the DIP switches, you can define a pump-up or pump-down, single or dual channel non-latching switch. The sensitivity adjustment (4.7k-100kOhms) allows you to define the input impedance at which the output relays (one Form A & one Form C) will change state, with a debounce time delay of 0.5 or 2 seconds.
Pre-order 6-8 Weeks
Functional Characteristics | |
Debounce Time | 0.5 or 2 seconds |
Probe Sense Voltage | 5vdc pulsed |
Output Characteristics | |
Output Contact Rating | |
Pilot Duty | 180VA @120VAC, C150 |
General Purpose | 5A @120VAC |
Relay Contact Life (Electrical) | 100,000 cycles min. @ rated load |
Relay Contact Life (Mechanical) | 10,000,000 cycles |
Description |
ISS-102A-LC Latching Controller ISS-102AA-DCS Dual Channel Switch ISS-102ACI-MC Multi-function Controller ISS-102C-M-LC MSHA* evaluated ISS-102CCI-M-MC MSHA* evaluated |
General Characteristics | |
Temperature Range | -20° to 55°C (-4° to 131°F) |
Maximum Input Power | 1.5 W |
Wire range | 12 to 20 AWG |
Terminal Torque | 3.5 to 4.5 in.-lbs. (max. 4.5 in.-lbs.) |
Provides Intrinsically-Safe | |
Circuits in the | |
following locations: |
Division 1 and 2 Class I, Groups A,B,C,D; Class II, Groups E,F,G; and Class III |
Standards Passed | |
Electrostatic Discharge (ESD) | IEC 61000-4-2, Level 3, 6kV contact, 8kV air |
Radio Frequency Immunity (RFI) | IEC 61000-4-3, Level 3, 10V/m |
Fast Transients | IEC 61000-4-4, Level 3, 4kV input power |
UL |
UL913 Sixth Edition (File #E233355) (except Models ISS-102C-M-LC & ISS-102CCI-M-MC which have been evaluated by MSHA) |
Dimensions |
H 88.9 mm (3.5”) W 52.93 mm (2.08”) D 59.69 mm (2.35”) |
Weight | 0.7 lb. (11.2 oz., 317.51 g) |
Mounting Method |
35mm DIN rail or Surface Mount (#6 or #8 screws) |