Littelfuse KRDR121A1, KRDR Series, 12VDC, Repeat Cycle Time Delay Relay SPDT (1 Form C) 1 Sec ~ 100 Sec Delay 10A @ 125VAC Chassis Mount

In stock
SKU: KRDR121A1
Regular price $157.35
Rated voltage

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The KRDR Series is a compact time-delay relay measuring only 2 in. (50.8 mm) square. Its solid-state timing circuit provides excellent repeat accuracy and stability. Encapsulation protects against shock, vibration, and humidity. The KRDR Series is a cost effective recycling timer for OEM applications that require small size, isolation, reliability, and long life.

Operation (Recycling - ON Time First)

Upon application of input voltage, the output relay energizes and the T2 ON time begins. At the end of the ON time, the output de-energizes and the T1 OFF time begins. At the end of the OFF time, the output relay energizes and the cycle repeats as long as input voltage is applied

Reset: Removing input voltage resets the output and the time delays, and returns the sequence to the ON time.

Operation (Recycling - OFF Time First)

Upon application of input voltage, the T1 OFF time begins. At the end of the OFF time, the T2 ON time begins and the load energizes. At the end of the ON time the load de-energizes, and the cycle repeats until input voltage is removed.

Reset: Removing input voltage resets the output and the sequence to the OFF time.

Pre-order 6-8 Weeks

Specifications

Time Delay
Range 0.1s - 1000m in 6 adjustable ranges or fixed
Repeat Accuracy ±0.5% or 20ms, whichever is greater
Tolerance (Factory Calibration) ≤ ± 5%
Recycle Time ≤ 150ms
Time Delay vs Temp. & Voltage ≤ ±5%
Input
Voltage 12, 24 or 110VDC; 24, 120 or 230VAC
Tolerance 12VDC & 24VDC/AC -15% - 20%
110VDC, 120 or 230VAC -20% - 10%
AC Line Frequency/DC Ripple 50/60 Hz / ≤ 10%
Power Consumption AC ≤ 2VA; DC ≤ 2W
Output
Type Isolated relay contacts
Form SPDT
Rating (at 40°C) 10A resistive @ 125VAC;
5A resistive @ 230VAC & 28VDC;
1/4 hp @ 125VAC
Max. Switching Voltage 250VAC
Life (Operations) Mechanical - 1 x 10⁷ ; Electrical - 1 x 10⁵
Protection
Polarity DC units are reverse polarity protected
Circuitry Encapsulated
Isolation Voltage ≥ 1500V RMS input to output
Insulation Resistance ≥ 100 MΩ
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Dimensions H 50.8 mm (2”)
W 50.8 mm (2”)
D 30.7 mm (1.21”)
Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage Temperature -20° to 60°C / -40° to 85°C
Humidity 95% relative, non-condensing
Weight ≅ 2.6 oz (74 g)