Littelfuse KSD1412S, KSD1 Series, 120VAC, On-Delay Time Delay Relay SPST-NO (1 Form A) Fixed, 2 Sec Delay Chassis Mount
FOR ALL ORDERS OUTSIDE CANADA, CUSTOMERS ARE RESPONSIBLE FOR ANY IMPORT DUTIES, TARIFFS, TAXES, AND CUSTOMS FEES THAT MAY APPLY TO THEIR ORDERS.
Couldn't load pickup availability
Use this text to encourage communication or promote sharing on social networks.
The KSD1 Series features two-terminal, series-connection with the load. The KSD1 Series is an ideal choice for delay-onmake timing applications. This series is designed for general purpose commercial and industrial applications where a small, cost effective, reliable solid-state timer is required. The factory calibration for fixed time delays is within 5% of the target time delay. The repeat accuracy, under stable conditions, is 0.5% of the selected time delay. This series is designed for popular AC and DC voltages. Time delays of 0.1 seconds to 1000 minutes are available in 6 ranges. The output is rated 1A steady and 10A inrush. The modules are totally solid state and encapsulated to protect the electronic circuitry.
Operation (Delay-on-Make)
Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed.
Reset: Removing input voltage resets the time delay and output.
Pre-order 6-8 Weeks
Specifications
| Time Delay | |
| Range | 0.1s - 1000m in 6 adjustable ranges or fixed |
| Type | Microcontroller with watchdog circuitry |
| Repeat Accuracy | ±0.5% or 20ms, whichever is greater |
| Tolerance (Factory Calibration) | ≤ ± 5% |
| Recycle Time | ≤ 150ms |
| Time Delay vs Temp. & Voltage | ≤ ±10% |
| Input | |
| Voltage | 24, 120, or 230VAC; 12 or 24VDC |
| Tolerance | ±20% |
| AC Line Frequency/DC Ripple | 50/60 Hz |
| Output | |
| Type | Solid state |
| Form | NO, open during timing |
| Maximum Load Current | 1A steady state, 10A inrush at 60°C |
| Minimum Holding Current | ≤ 40mA |
| OFF State Leakage Current | ≅ 7mA @ 230VAC |
| Voltage Drop | ≅ 2.5V @ 1A |
| Protection | |
| Polarity | DC units are reverse polarity protected |
| Circuitry | Encapsulated |
| Dielectric Breakdown | ≥ 2000V RMS terminals to mounting surface |
| Insulation Resistance | ≥ 100 MΩ |
| Mechanical | |
| Mounting | Surface mount with one #10 (M5 x 0.8) screw |
| Dimensions |
H 50.8 mm (2”) W 50.8 mm (2”) D 30.7 mm (1.21”) |
| Termination | 0.25 in. (6.35 mm) male quick connect terminals |
| Environmental | |
| Operating/Storage Temperature | -40° to 60°C / -40° to 85°C |
| Humidity | 95% relative, non-condensing |
| Weight | ≅ 2.4 oz (68 g) |