Littelfuse KSD3310.1SA, KSD3 Series, 24VDC, Repeat Cycle Time Delay Relay SPST-NO (1 Form A) Fixed, 0.1 Sec Delay Chassis Mount

In stock
SKU: KSD3310.1SA
Regular price $90.47
Rated voltage

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The KSD3 Series Digi-Timer is a cost effective approach for ON/OFF recycling applications. The on time is equal to the off time. An adjustment of the RT will change the time delays of both on and off times. This series is designed for general purpose commercial and industrial applications where a small, cost effective, reliable, solid-state timer is required. The factory calibration for fixed time delays is within 5% of the target time delay. The repeat accuracy, under stable conditions, is 0.5% of the selected time delay. This series is designed for popular AC and DC voltages. Time delays of 0.1 seconds to 1000 minutes are available in 6 ranges. The output is rated 1A steady and 10A inrush. The modules are totally solid state and encapsulated to protect the electronic circuitry.

Operation (Recycling Flasher - ON Time First)

Upon application of input voltage, the output energizes and the T1, ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied.

Reset: : Removing input voltage resets the output and time delays, and returns the sequence to the ON time

Operation (Recycling Flasher - OFF Time First)

Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of the ON time the load de-energizes, and the cycle repeats until input voltage is removed.

Reset: Removing input voltage resets the output and time delays and the sequence to the OFF time.

Specifications

Time Delay
Range 0.1s - 1000m in 6 adjustable ranges or fixed
Repeat Accuracy ±0.5% or 20ms, whichever is greater
Tolerance (Factory Calibration) ≤ ± 5%
Reset Time ≤ 150ms
Time Delay vs Temp. & Voltage ≤ ±10%
Input
Voltage 24 or 120VAC; 12 or 24VDC
Tolerance ±20%
AC Line Frequency 50/60 Hz
Power Consumption AC ≤ 2VA; DC ≤ 1W
Output
Type Solid state
Maximum Load Current 1A steady state, 10A inrush at 60°C
OFF State Leakage Current AC ≅ 5mA @ 230VAC; DC ≅ 1mA
Voltage Drop AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A
DC Operation Negative switching only
Protection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
Polarity DC units are reverse polarity protected
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Dimensions H 50.8 mm (2”)
W 50.8 mm (2”)
D 30.7 mm (1.21”)
Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage Temperature -40° to 60°C / -40° to 85°C
Humidity 95% relative, non-condensing
Weight ≅ 2.4 oz (68 g)