Littelfuse LLC643F26M, LLC6 Series, Liquid Level Controller Low Level SPDT, 120VAC, Plug-in Socket, 3s Fixed

In stock
SKU: LLC643F26M
Regular price $174.05
Rated voltage
Contact code

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The LLC6 Series is a plug-in, single-probe conductive liquid level control designed for low liquid level cutoff protection. It offers a factory fixed time delay of 1 - 60s and is available in input voltages of 24, 120, or 230VAC. LED indicator illuminates whenever the LLC6’s 10A, SPDT output relay is energized. Available with automatic/manual reset or a special manual reset with power outage feature, which auto resets the unit when power is restored and the water level is acceptable. 24VAC and 120VAC units are recognized as limit switches under UL353 (230VAC units are UL508) and CSA certified under Standard 14.

Operation

Automatic Reset (Reset terminals not connected): When liquid rises to the low level cutoff probe, the output relay and the LED indicator energize. When the liquid falls below low level cutoff probe, the output relay and the LED indicator de-energize after a fixed time delay.

Manual Reset (Reset switch connected): When the liquid level falls below the low level probe, the output relay and LED de-energize after a fixed time delay. When the liquid level rises to the low level probe, the output relay and LED indicator remain de-energized until the manual reset switch is opened; then they energize immediately.

Power Outage Manual Reset (Reset switch connected): A power outage causes the output relay and LED indicator to de-energize. Upon restoration of power, if the liquid level is above the low level probe, the output relay and LED indicator will re-energize. If the liquid level is below the low level probe, the output relay and LED indicator remain de-energized until the Normally Closed (NC) reset switch is opened.

Pre-order 6-8 Weeks

Control
Type ON/OFF (single level) resistance sensor with built-in time delay to prevent rapid cycling
Sense Voltage 12VAC nominal at probe terminals
Sense Resistance Fixed 5K - 250KΩ
Sense Resistance Tolerance Fixed ±10%
Time Delay
Range 1 - 60s in 1s increments
Tolerance ±20%
Repeat Accuracy ±10%
Time Delay vs Temp. & Voltage ±10%
Power Outage Reset Delay ≤ 1s
Input
Voltage 120VAC
Tolerance +10% to -20%
AC Line Frequency 50/60 Hz
Output
Type Electromechanical relay
Form Non-isolated, SPDT
Rating 10A resistive @ 240VAC; 1/4 hp @ 125VAC;
1/2 hp @ 250VAC
Protection
Surge IEEE C62.41-1991 Level A
Isolation Voltage ≥ 2500V RMS between input & output terminals
Mechanical
Mounting Plug-in socket
Termination 11-pin relay type
Dimensions (Open Board) H  73.9 mm (2.91”)
W 60.7 mm (2.39”)
D  45.2 mm (1.78”)
Environmental
Operating/Storage Temperature -40° to 60°C / -40° to 80°C
Humidity 95% relative, non-condensing
Weight ≅ 7.3 oz (207 g)