Littelfuse RS4A22, RS Series, 120VAC, Repeat Cycle Time Delay Relay SPST-NO (1 Form A) 0.1 Min ~ 102.3 Min Delay Chassis Mount

In stock
SKU: RS4A22
Regular price $231.06
Rated voltage
First delay

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The RS Series is a solid-state, encapsulated, recycling timer designed for tough industrial environments. It is used by many testing labs as a life cycle tester; by others as a cycle controller. The RS Series has separate DIP switch adjustments for the on delay and the off delay. These make accurate adjustment possible the first time, every time. Time delays of 0.1 seconds to 1023 hours are available in 4 ranges.

Operation (Recycling - ON Time First)
Upon application of input voltage, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied.

Reset: Removing input voltage resets the output and time delays, and returns the sequence to the ON time.

Operation (Recycling - OFF Time First)
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the output energizes and the T1 ON time begins. At the end of the ON time, the output de-energizes and the cycle repeats as long as input voltage is applied.

Reset: Removing input voltage resets the output and time delays, and returns the sequence to the OFF time.

*For CE approved applications, power must be removed from the unit when a switch position is changed.
Time Delay
Range* 0.1 - 102.3s in 0.1s increments
0.1 - 102.3m in 0.1m increments
1 - 1023m in 1m increments
1 - 1023h in 1h increments
Repeat Accuracy ±0.1% or 20ms, whichever is greater
Setting Accuracy ≤ ±2% or 20ms, whichever is greater
Reset Time ≤ 150ms
Time Delay vs Temp. & Voltage ≤ ± 2%
Input
Voltage 12, or 24VDC; 24, 120, or 230VAC
Tolerance ±20%
AC Line Frequency/DC Ripple 50/60 Hz / ≤ ±10%
Power Consumption AC ≤ 2VA; DC ≤ 1W
Output
Type Solid state
Maximum Load Current 1A steady state, 10A inrush at 60°C
OFF State Leakage Current AC ≅ 5mA @ 230VAC; DC ≅ 1mA
Voltage Drop AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A
Protection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
Polarity DC units are reverse polarity protected
Mechanical
Mounting Surface mount with one #10 (M5 x 0.8) screw
Termination 0.25 in. (6.35 mm) male quick connect terminals
Dimensions H 76.7 mm (3”)
W 50.8 mm (2”)
D 38.1 mm (1.5”)
Environmental
Operating/Storage Temperature -40° to 75°C / -40° to 85°C
Weight ≅ 3.9 oz (111 g)
Humidity 95% relative, non-condensing