Littelfuse TDB230AL, TDB Series, Relay-Output, Delay-on-Break Timer, 230VAC, 1–1023s Time Setting, 8 Pins, SPDT Contact Form

In stock
SKU: TDB230AL
Regular price $203.18
Rated voltage
Contact code

Use this text to encourage communication or promote sharing on social networks.

You can also add links

The TDB Series combines accurate digital circuitry with isolated, 10A, DPDT or SPDT contacts in an 8 or 11-pin plug-in package. The TDB Series features DIP switch selectable time delays ranging from 0.1-10,230 seconds in three ranges. The TDB Series is the product of choice for custom control panel and OEM designers.

Operation (Delay-on-Break)
Input voltage must be applied to the input before and during timing. Upon closure of the initiate switch, the output relay is energized. The time delay begins when the initiate switch is opened (trailing edge triggered). The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied.
Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output.

Pre-order 6-8 Weeks

*UL Listed when used with Part Number OT08-PC, RB08-PC, OT11-PC, or RB11-PC manufactured by Custom Connector Corp.

Note: Manufacturer's recommended screw terminal torque for the OT series sockets is 12 in-lbs.

Time Delay
Type Digital integrated circuitry
Range 0.1–102.3 s in 0.1 s increments
1–1023 s in 1 s increments
10–10,230 s in 10 s increments
Repeat Accuracy ±0.1 %
Setting Accuracy ±2 %
Reset Time ≤ 150 ms
Time Delay vs Temp. & Voltage ±5 %
Indicator LED indicates relay is energized
Initiate Time ≤ 60 ms
Input
Voltage 12, 24/28 V dc; 24, 120, or 230 V ac
Tolerance 12 V dc & 24 V dc/ac      -15% – 20%
120 & 230 V ac                -20% – 10%
AC Line Frequency 50/60 Hz
Power Consumption ≤ 3.25W
Output
Type Electromechanical relay
Form SPDT or DPDT
Rating 8 A resistive @ 120/240 V ac;
1/3 hp @ 120/240 V ac
Life Mechanical - 1 x 107 ; Electrical - 1 x 10⁶
Protection
Isolation Voltage ≥ 1500 V rms input to output
Polarity Dc units reverse polarity protected
Mechanical
Mounting Plug-in socket
Dimensions H 44.45 mm (1.75”); W 60.33 mm (2.38”);
D (with socket) 104.78 mm (4.13”)
Termination Octal 8-pin plug-in or 11-pin plug-in
Environmental
Operating/Storage Temperature -20 °C to 65 °C / -30 °C to 85 °C
Safety Marks UL (socket required)* UL 508 (E57310)
Weight ≅ 4 oz (113 g